EVCO S.p.A. | EV3143 | Instruction sheet ver. 1.0 | Code 1043143E103 | Page 1 of 3 | PT 22/19 

EV3143 

Controller with two independent regulators for refrigerated milk storage  

units and ice cream batch freezers 

 

 

 

 

EN 

ENGLISH 

230 VAC or 115 VAC power supply (according to the model) 

2 analogue inputs (PTC/NTC) 

-   

door switch/multi-purpose input 

main relay 16 A res. @ 250 VAC 

alarm buzzer 

TTL MODBUS slave port for BMS 

hot or cold mode regulation. 

 

MEASUREMENTS AND INSTALLATION 

Measurements in mm (inches). To be fitted to a panel, snap-in brackets provided. 

 

 

 

INSTALLATION PRECAUTIONS 

the thickness of the panel must be between 0.8 and 2.0 mm (1/32 and 1/16 in) 

ensure that the working conditions are within the limits stated in the TECHNICAL SPEC-

IFICATIONS section 

do not install the device close to heat sources, equipment with a strong magnetic field, 

in places subject to direct sunlight, rain, damp, excessive dust, mechanical vibrations or 

shocks 

in compliance with safety regulations, the device must be installed properly to ensure 

adequate protection from contact with electrical parts. All protective parts must be fixed 

in such a way as to need the aid of a tool to remove them. 

 

ELECTRICAL CONNECTION 

 

 

N.B. 

-  use cables of an adequate section for the current running through them 

-  to reduce any electromagnetic interference, locate the power cables as far away as 

possible from the signal cables. 

 

 

 

The controller is operated mainly by P10 (default "controller with two independent regulators"). 

 

P10 

OPERATION 

PROBE 1 

PROBE 2 

LOAD 1 

LOAD 2 

LOAD 3 

 

controller with two inde-

pendent regulators  

regulator 

regulator 

regulator 

regulator 

alarm 

 

 

controller for refrigerated 

milk storage units 

tank 

 

auxiliary 

 

compres-

sor 

auxiliary 

 

beater 

 

 

controller  for  ice  cream 

batch freezers  

tank 

 

plate 

 

compres-

sor 

plate 

heaters  

beater 

 

 

PRECAUTIONS FOR ELECTRICAL CONNECTION 

if using an electrical or pneumatic screwdriver, adjust the tightening torque 

if the device is moved from a cold to a warm place, humidity may cause condensation 

to form inside. Wait for about an hour before switching on the power 

make  sure  that  the  supply  voltage, electrical  frequency  and  power are  within  the  set 

limits. See the section TECHNICAL SPECIFICATIONS 

disconnect the power supply before carrying out any type of maintenance 

do not use the device as a safety device 

for repairs and for further information, contact the EVCO sales network. 

 

FIRST-TIME USE 

1. 

Carry out the installation following the instructions given in the section MEASUREMENTS 

AND INSTALLATION

2. 

Power up the device as set out in the section ELECTRICAL CONNECTION: an internal test 

will start up. 

 

The test normally takes a few seconds; when it is finished the display will switch off. 

3. 

Configure the device as shown in the section Setting configuration parameters

 

Recommended configuration parameters for first-time use: 

PAR. 

DEF. 

PARAMETER 

MIN... MAX. 

SP1 

0.0 

load 1 setpoint 

r1... r2 

SP2 

0.0 

load 2 setpoint 

r12... r13 

SP3 

0.0 

beater setpoint 

r16... r17 

P0 

type of probe 

0  = PTC 

1  = NTC 

P2 

temperature measurement unit 

0  = °C 

1  = °F 

P10 

 

 

 

 

 

 

 

 

 

 

operating logic 

 

 

 

 

 

0  = controller  with  two  independent 

regulators 

1  = controller  for  refrigerated  milk 

storage units 

2  = controller  for  ice  cream  batch 

freezers 

 

 

Then check that the remaining settings are appropriate; see the section CONFIGURATION 

PARAMETERS

4. 

Disconnect the device from the mains. 

5. 

Make the electrical connection as shown in the section ELECTRICAL CONNECTION, with-

out powering up the device. 

6. 

When connecting to an RS-485 network, connect the EVIF22TSX interface; see the rele-

vant instruction sheets. 

7. 

Power up the device again. 

 

 

 

 

 

 

 

USER INTERFACE AND MAIN FUNCTIONS 

 

 

 

4.1 

Switching the device on/off 

1. 

 

If POF = 1 (default), touch the ON/STAND-BY key for 4 s. 

If the device is switched on, the display will show the P5 value ("probe 1 temperature" default); 

if the display shows an alarm code, see the section ALARMS

LED 

ON 

OFF 

FLASHING 

 

compressor on 

 

 

compressor off 

 

 

-  compressor  protection  in  pro-

gress 

-   setpoint being set 

 

plate heaters on 

 

plate heaters off 

 

setpoint being set 

 

OUT1 

regulator 1 on 

 

regulator 1 off 

 

-   load 1 protection in progress 

-   setpoint being set 

 

defrost active 

 

 

 

 

beater on 

 

beater off 

 

setpoint being set 

 

 

alarm  active  and  si-

lenced 

 

alarm active and not silenced 

 

°C/°F 

temperature displayed 

 

 

 

OUT2 

regulator 2 on 

 

regulator 2 off 

 

-   load 2 protection in progress 

-   setpoint being set 

 

device off 

 

device on 

 

device being switched on/off 

 

 

When 30 s have elapsed without the keys being pressed, the display will show the “Loc” label 

and the keypad will automatically lock. 

 

4.2 

Unlocking the keypad 

Touch a key for 1 s: the display will show the label “UnL”. 

 

4.3 

Quick setting: 

 

-  of setpoints (if P9 = 1 or 3) 

 

-  beater switch on/off times (if P9 = 2 or 3) 

Check that the keypad is not locked. 

1. 

 

Touch the SET key: the display will show the label “SP1”. 

2. 

 

Touch the UP or DOWN key within 15 s to set the load 1 setpoint 

value within the limits r1 and r2 (default “-50... 50”). 

3. 

 

Touch the SET key: the display will show the label “SP2”. 

4. 

 

Touch the UP or DOWN key within 15 s to set the load 2 setpoint 

value within the limits r12 and r13 (default “-50... 50”). 

5. 

 

Touch the SET key: the display will show the label “SP3”. 

6. 

 

Touch the UP or DOWN key within 15 s to set the beater setpoint 

value within the limits r16 and r17 (default “-50... 50”). 

7. 

 

Touch the SET key: the display will show the label “t0”. 

8. 

 

Touch the UP or DOWN key within 15 s to set the time the beater 

is switched off within the limits 0... 240 min. 

9. 

 

Touch the SET key: the display will show the label “t1”. 

10. 

 

Touch the UP or DOWN key within 15 s to set the time the beater 

is switched on within the limits 0... 240 min. 

11. 

 

Touch the SET key (or take no action for 15 s). 

Settings are temporary: when the device is switched back on (and after a power failure), it resets 

the values SP1, SP2, SP3, t0 and t1. 

 

4.4 

Starting up/interrupting batch freezing (if P10 = 2) 

Check that the keypad is not locked. 

1. 

 

Touch the ON/STAND-BY key. 

 

4.5 

Manually switching on the beater (if P10 = 1) 

Check that the keypad is not locked. 

1. 

 

Touch the DOWN key for 4 s. 

The beater is switched on for time t1. 

 

4.6 

Activating manual defrost (if r5 and/or r19 = 0, default) 

Check that the keypad is not locked. 

1. 

 

Touch the UP key for 4 s. 

 

4.7 

Silencing the buzzer (if Pbu = 2 or 3) 

Touch a key. 

If u4 = 1, the alarm output is also deactivated. 

 

OPERATION 

5.1 

Controller with two independent regulators (P10 = 0, default) 

Cold mode regulation regulator 1 (r5 = 0). 

 

 

Hot mode regulation regulator 1 (r5 = 1). 

 

 

 

 

 

 

 

 

 

 

 

Cold mode regulation regulator 2 (r10 = 0). 

 

 

Hot mode regulation regulator 2 (r10 = 1). 

 

 

5.2 

Controller for refrigerated milk storage units (P10 = 1) 

Compressor operation. 

 

 

Beater operation set to t0 and t1 (r14 = 0). 

 

 

Beater operation set to r19, t0 and t1 if beater setpoint is not reached (r14 = 1). 

Cold mode regulation beater (r19 = 0) 

 

 

Beater operation set to r19, t0 and t1 if beater setpoint is not reached (r14 = 1). 

Hot mode regulation (r19 = 1). 

 

 

5.3 

Controller for ice cream batch freezers (P10 = 2) 

The batch freezing cycle consists of 4 phases: 

heating 

cooking 

cooling 

conservation. 

 

5.3.1  Heating 

The compressor remains off. 

 

Plate heaters operation. 

 

 

Beater operation. 

 

 

End of phase.  

 

 

At the end of the phase the buzzer emits 10 beeps 1 s long. 

If there is a power failure during the phase, it starts back up again from the beginning.  

 

5.3.2  Cooking 

The compressor remains off. 

 

Plate heaters operation. 

 

 