Страница 2: ...lation distances 11 3 2 Installation Basic Plus Interfaces 13 3 2 1 Dimensions Basic Plus Interfaces 13 CHAPTER 4 ELECTRICAL CONNECTIONS 14 4 1 Connection best practice 14 4 1 1 Wiring guidelines 15 4 2 Wiring diagram Inverter 16 4 2 1 Earthing 17 4 3 Wiring diagram Basic Plus Interface 17 4 4 Inverter Interface connection 18 CHAPTER 5 USER INTERFACE 19 5 1 Touch keys 19 5 2 Icons 19 5 2 1 Basic I...

Страница 3: ...al inputs 27 6 3 1 Digital input 1 27 6 3 2 Digital input 2 28 6 3 3 Digital input 3 28 CHAPTER 7 PARAMETERS 29 7 1 Table of configuration parameters 29 CHAPTER 8 ALARMS 30 8 1 Table of alarms 30 CHAPTER 9 PARAMETERS MANAGER 31 CHAPTER 10 WARRANTY 33 ...

Страница 4: ... specific application or use Users can send us comments and suggestions on how to improve or correct this publication Neither EVCO nor any of its associates or subsidiaries shall be held responsible or liable for improper use of the information contained herein EVCO has a policy of continuous development Therefore EVCO reserves the right to make changes and improvements to any product described in...

Страница 5: ...to death or serious injury CAUTION CAUTION indicates a potentially hazardous situation which if not avoided could cause minor or moderate injury NOTICE NOTICE indicates a situation not related to physical injuries but which if not avoided could damage the equipment NOTE The maintenance repair installation and use of electrical equipment must only be entrusted to qualified personnel QUALIFIED PERSO...

Страница 6: ...ual voltage Do not open disassemble repair or modify the product Before handling the product make sure you are wearing all the necessary personal protective equipment PPE Do not expose the equipment to liquids or chemicals Before applying voltage to the inverter Make sure the running period has been completed and no parts of the system can become hazardous If the mains power supply terminals and t...

Страница 7: ... WARNING MALFUNCTIONING OF THE EQUIPMENT Perform the wiring carefully in compliance with electromagnetic compatibility requirements Do not operate the product with unknown or incorrect settings or data Carry out a full start up test Make sure the wiring is correct for the settings Use shielded cables for all I O signal and communication cables Use double shielded cables for motor wiring Minimise t...

Страница 8: ...ge during operation Motor alarm display Plus You can set 10 rotation speeds and mixing cycles with up to 10 stages The time for each stage may vary between 1 and 99 minutes and can be customised There are several functions such as Play Pause Reverse to remove the dough mixture from the spiral attachment Speed change during operation Motor alarm display 1 1 COMPLIANCE 2014 35 UE Low voltage directi...

Страница 9: ...Hz Serial communication port properties SELV RS 485 serial port 1 opto isolated RS 485 MODBUS RTU Slave serial port reinforced for connection with Basic Plus interface Maximum baud rate 38400 bps Maximum cable length 1 5 m 4 9 ft Compliance CE in accordance with directives EN61800 3 and EN61800 5 1 in C2 category 2 2 TECHNICAL SPECIFICATIONS BASIC PLUS INTERFACES The product complies with the foll...

Страница 10: ... earthed and circuited remove the earth and short circuits on these terminals Make sure all the equipment is properly earthed Make sure all protective elements such as covers hatches and grilles are fitted and or closed Check all wiring connections This device was designed to operate in non hazardous environments excluding applications that generate or could potentially generate hazardous atmosphe...

Страница 11: ...on and aeration of the system Make sure there is a distance of at least 10 mm 0 39 in between the support base and the cooler WARNING HOT SURFACES Avoid all contact with hot surfaces Do not leave flammable or heat sensitive components on or near hot surfaces Make sure the product has cooled sufficiently before handling it Make sure sufficient heat dissipation takes place by performing a test under...

Страница 12: ... 12 144XXXME4 00 06 2020 EV3 Mix 40 1 57 mm in 40 1 57 40 1 57 40 1 57 Fig 4 Minimum inverter installation distances front view ...

Страница 13: ...0 EV3 Mix 3 2 INSTALLATION BASIC PLUS INTERFACES 71 2 79 29 1 14 mm in Fig 5 Installing Basic Plus interfaces 3 2 1 Dimensions Basic Plus Interfaces 33 1 30 75 2 95 69 2 71 59 2 32 mm in Fig 6 Basic Plus interface dimensions ...

Страница 14: ...ly Use a suitably calibrated and electrically insulated Voltmeter to make sure the power supply is disconnected Wait for 5 minutes after disconnecting the power supply before installing uninstalling accessories hardware cables or wires to allow the condensers to discharge Do not open disassemble repair or modify the product Before handling the product make sure you are wearing all the necessary pe...

Страница 15: ... Make sure the operating environment and conditions fall within the specified values Use wires with the correct diameter suited to the voltage and current requirements Use copper conductors compulsory Use shielded twisted pair cables for analogue digital I O connections Use shielded twisted pair cables for network and RS 485 serial connections Use correctly earthed shielded cables for all inputs o...

Страница 16: ...EARTH Power supply input RS 485 RS 485 serial port for remote connection U Motor control output V Motor control output W Motor control output PE Motor earth connection COM Digital input common NC Alarm relay output normally closed C Relay output common NO Alarm relay output normally open ID1 Digital input 1 Stop Run ID2 Digital input 2 Motor thermal switch ID3 Digital input 3 Reset alarms NOTE For...

Страница 17: ... all the equipment is properly earthed M Fig 7 Inverter earthing 4 3 WIRING DIAGRAM BASIC PLUS INTERFACE Vdc GND TERMINALS 21 12 Vdc power supply connection from Inverter 22 RS 485 serial port connection with Inverter 23 RS 485 serial port connection with Inverter 24 RS 485 GND serial port connection with Inverter ...

Страница 18: ...4 4 INVERTER INTERFACE CONNECTION The wiring diagram below illustrates how to connect the inverter to one of the interfaces Basic or Plus Vdc Basic Plus Interface Inverter 21 22 23 24 B A GND Vdc GND Fig 8 Inverter Interface connection ...

Страница 19: ...st When it is first switched on the display will flash for 8 seconds to make sure the icons are shown correctly Once the Lamp Test is complete the device will revert to the status it was in before it was switched off The icons used by each model are described below 5 2 1 Basic Interface The icons used by the Basic interface are described below Icon description Lit steadily Configuration or Stage 1...

Страница 20: ...ycle paused Off Rotation cycle not active Lit steadily Motor not in motion Not used Flashing Reverse motor operation Flashing Alarm active alarm code displayed Lit steadily Automatic mode active Lit steadily Time value displayed Flashing Rotation cycle paused 5 3 FUNCTIONS MENU The following section explains which menus are available in the EV3 Mix and how to navigate them 5 3 1 Select start manua...

Страница 21: ...f actions to complete in order to start the food mixer rotation cycle manually and change its speed is described below Sequence Description Touch to enter the Select start manual cycle menu Touch to scroll through the available speeds and select the desired level See 6 1 SETTING THE SPEED ON PAGE 26 Touch to confirm the selection and start the rotation cycle The bottom display will show the text M...

Страница 22: ...t automatic cycle with 1 2 stages menu 1 2 Touch to select the duration of stage 1 and press to confirm 1 2 Touch to scroll through the available speeds and press to confirm HI Maximum speed Md Medium speed LO Minimum speed See 6 1 SETTING THE SPEED ON PAGE 26 1 2 Touch to select the duration of stage 2 and press to confirm 0 Stage not applied 1 2 Touch to scroll through the available speeds and p...

Страница 23: ...s Interface The sequence of actions to complete in order to start the food mixer automatic rotation cycle with 1 to 10 stages manually is described below Sequence Description Touch to enter the Select start automatic cycle with 10 stages menu 1 2 Touch to select the duration of stage 1 and touch to confirm 1 2 Touch to scroll through the available speeds and press to confirm and start the rotation...

Страница 24: ...ond cycle countdown timer Once this has elapsed the display will revert to how it was when the device was in stop mode Plus Interface Sequence Description When the device is in STOP Touch for 2 seconds to start a short manual reverse rotation cycle 10 seconds of rotation The device will show the 10 second cycle countdown timer on the bottom display Once this has elapsed the display will revert to ...

Страница 25: ...ocedure is the same for both interfaces Sequence Description When the device is in stop mode touch for 3 seconds The text PA will appear touch and release 1 2 Set the password value for the level you want to enter by touching or and touch to confirm Passwords 19 Password value to enter OEM parameters O 19 Password value to enter Expert parameters E ...

Страница 26: ...nge Setting B04 Maximum motor speed rpm B05 6000 1500 B05 Minimum motor speed rpm 150 B04 300 The speeds that can be set via the basic interface are Maximum speed Hi Medium speed Md Minimum speed Lo The device calculates the medium speed between the two values B04 and B05 as shown in the graph below Speed 0 B05 Cycle Start Increment 1 Increment 2 B04 B04 B05 2 Fig 9 Setting the speed Basic interfa...

Страница 27: ...AL INPUTS 6 3 1 Digital input 1 Digital input 1 is dedicated to opening and closing the cover of the food mixer With ID1 closed food mixer cover closed the food mixer manual or automatic cycle can be started With ID1 open food mixer cover open if a cycle is in progress it will be paused and the code US will appear on the display alternating with the current display for the Plus interface it will b...

Страница 28: ...ID2 closed when a cycle is in progress the latter is set to STOP status The motor thermal switch alarm is reset manually to reset the alarm close and reopen digital input 3 or disconnect and reconnect the device power supply 6 3 3 Digital input 3 Digital input 3 is dedicated to alarm resetting as described in the previous paragraphs ...

Страница 29: ...trol type applied to the motor 1 Scalar 2 Vector NOTE Contact EVCO technical support for setting A03 2 1 2 1 1 1 E SPEED GROUP B B02 Acceleration ramp Time required to reach the nominal speed from 0 rpm s 0 2 200 0 3 0 3 0 3 0 O B03 Deceleration ramp Time required to reach 0 rpm from the nominal speed s 0 2 200 0 5 0 5 0 5 0 O B04 Maximum motor speed 1 rpm 0 12000 1500 1500 1500 O B05 Minimum moto...

Страница 30: ...set alarm via input ID3 OT Cooler overtemperature alarm 6 The motor has reached and exceeded the maximum temperature of 90 C The alarm resets automatically when the motor temperature drops to 10 C 50 F below the set temperature threshold of 90 C Reset alarm via input ID3 EP Eeprom data alarm 8 The data structure is not intact The default values are restored automatically The parameters changed pre...

Страница 31: ...he settings correctly to connect to the EV3 Mix as shown in the image below Connection Setup PC settings Serial Connection COM PhysicalComPort Serial port Baud rate Parity Hardware USBAdapter COM35 VCP0 9600 None Previous Next DIRECT MODBUS Protocol Fig 11 Communication port setting Press NEXT to continue and configure the network scan settings Connection Setup Scan devices network Serial Connecti...

Страница 32: ...en will appear otherwise you will need to reconfigure the settings properly Connection Setup End 1 N MODBUS 1 Baud 9600 Parity None 1020 1 1020AA01 Address Resul code Status Driver Previous Close Fig 13 EV3 Mix detection Press Close to proceed with the EV3 Mix parameter configuration screen ...

Страница 33: ...warranty is limited to product repair or depending on the sole opinion of the manufacturer replacement The warranty does not cover damage malfunctioning leaks or requests for compensation due to Operator error during use and or installation Modifications carried out by the purchaser Unauthorised repairs Dropping and or damaging the device Natural disasters fires lightning floods Incorrect storage ...

Страница 34: ...y Code CPI EVCO forbids the reproduction and distribution even in part of the contents unless express authorisation is obtained directly from EVCO The customer manufacturer installer or end user assumes all responsibility for device configuration EVCO does not assume any responsibility for potential errors and reserves the right to make any changes at any time without the basic functional and safe...