ZyWAN - User Manual
122
110150-1001F
Terminal Server Setup
This Terminal Server configuration uses “Full Duplex” mode, which allows full bi-directional communication.
This example also shows the use of COM2 (RS-232) at a baud rate of 19,200, which must be set correctly
for the application. If RS-485 is needed (on an appropriate model of ZyWAN), use COM3 with ”Flow Control”
set to
RTS/CTS
and “Echo cancel RS485” set to
Yes
. See
Terminal Servers
on page
100
for more details
on other Terminal Server options.
The following screen capture shows the
Terminal Servers
configuration page.
Networking Setup
Port 4000 (TCP) must be opened in the firewall to allow external connections to be made to the Terminal
Server.
The following screen capture shows the
Networking
configuration page.