background image

BA_S003 
Operation Manual 

EUROTEC Antriebszubehör GmbH | Bildstock 37 | DE-88085 Langenargen | [email protected] | www.eurotec-shop.com | 24.04.2018 | Seite 1 von 2

 

 

Product Group: 

Solenoid valve 

Product type: 

MF52... / MF32... 

EN 

 
To ensure functionality and your own safety, please read these operating instructions carefully before you begin the installation. If you have 
any further questions, please contact: 
 
EUROTEC Antriebszubehör GmbH 
Tel.  +49 (0) 7543 93463 - 0 | Fax. - 10 | 

[email protected]

 | 

www.eurotec-shop.com

 

1.

 

Device description 

The in-line solenoid valve, series MF52... / MF32... is intended to be used to control single and double acting, pneumatic swivel drives or 
cylinders with compressed air. It is not intended for use with liquids or gases. 
The solenoid valves, series MF52… do have a 5/2 way function and are intended to be used to control double acting, pneumatic swivel drives 
or cylinders. The solenoid valves, series MF32… do have a 3/2 way function and are intended to be used to control single acting, pneumatic 
swivel drives or cylinders. 

2.

 

Labeling and intended use 

The solenoid valve, type MF52... / MF32... must not be used in an area subject to explosion hazards. For use in areas subject to explosion 
hazards, a different version of the valve and its accompanying operating instructions is required. These operating instructions are to be used 
with the trip coil manufacturer’s operating instructions. The trip coil manufacturer’s operating instructions relate to the electrical part of 
the device and the operation instructions in this manual relate to the non-electrical part.  The label on the valve body varies according to 
function and design. 
 
On the  solenoid valve sticker you will find the item number, name and complete address of the manufacturer, the company logo, the CE 
symbol, the year of manufacture, the pneumatic circuit diagram, the numbering of the connections and the solenoid valve data.  

3.

 

Safe installation 

To avoid mistakes, only a specialist is permitted to set up, connect and put the devices into operation. Always observe the following safety 
instructions before set up: 
 

 

IF you do not observe the safety instructions in these operational instructions or if you use or handle the device 
improperly, our staff cannot be held liable. Furthermore your warranty for the device and its accessory 
components will be void! 

 

 When removing packaging, ensure that no particles of dirt enter the device. 

 Check the label to see whether the device is suitable for your application. 

 Observe national regulations and conditions, the relevant set up requirements and the  

     general rules of the trade. 

 Take suitable measures to prevent unintentional activation of or improper interference with the   

     device. 

 Ensure that the cables and cannot become detached under pressure. 

 Ensure that the connecting cable is sufficiently relieved of strain or fix it securely. 

 Actively protect the device and cable against damage.  

 Avoid bending the air supply cord too sharply. 

 Do not exceed an outer diameter of 20mm for tubes and bundles of cables. 

 Install the device so that it is accessible for regular cleaning. 

 Before installation, ensure that all machines/systems meet the EMV guidelines. 

 Avoid the build up of static in peripheral equipment. Connect all conductive metal parts including  

     accessories to calculate the potential balance. 

 Observe the trip coil manufacturer’s operation instructions for electrical installation. 

 The device must only be used in a finished assembled condition. 

 

 

Do not seal unused openings! The valve would then no longer function properly. The piston in the valve body will 
no longer be able to move after a few circuits because of the accumulation of condensed air. Instead, use 
suitable air-permeable mufflers to prevent dirt from getting inside the valve. 

4.

 

Assembly 

The solenoid valves, series MF52... / MF32... can be fixed with standard DIN screws to any solid ground with the matching drill pattern. It is 
not possible and non-functional to mount these solenoid valves directly on pneumatic NAMUR swivel drive motors. 
 
 

Отзывы: