background image

EUROSTER 12M 

 USER MANUAL 

 

1

 

 
 

EUROSTER 12M 

WEATHER-BASED CONTROLLER FOR THE HEATING ZONE 

Manual version: 01.08.2016 

MANUFACTURER: P.H.P.U. 

AS, Chumiętki 4, 63

-840 Krobia, Poland 

1. INTRODUCTION 

In order to take full advantage of the controller capabilities and ensure proper  operation 
of the heating system, please read this user manual carefully. 

2. APPLICATION 

EUROSTER  12M

  is  a  universal  weather-based  controller  designed  for  control  

of a heating zone equipped with a mixing valve with a three-point actuator and a central 
heating zone pump. 
All  parameters  are  shown  on  the  legible  graphical  display,  and  the  device  is  very  easy  
to control with a knob and a button. 

3. BASIC FUNCTIONS OF THE CONTROLLER 

 

Control of a 3-point actuator of a mixing valve 

 

Control of a heating zone pump 

 

Weather-based setting of a heating zone preset temperature 

 

Weekly operating schedule 

 

Cooperation with a room thermostat 

 

Switching the heating off automatically in case of external temperature increase 

 

Function  of  switching  a  zone  on  temporarily  with  a  preset  temperature  (floor 
preheating, fast heating up of rooms) 

 

Zone overheating protection, frost protection 

 

Alarm indication 

 

Ability of test switch-on of outputs 

 

Anti-Stop system 

 protection of pumps against seizure 

 

legible, graphic, backlit LCD 

 

Set of temperature sensors included  

 

EUROSTER  12M 

controller  is  equipped  with  an  Anti-Stop  system  that  prevents  the 

process of scale build-up on the unused pump rotor and the mixer. It automatically turns 
the  pump  and  the  mixer  on  every  10 days  when  the  heating  season  is  over.  Keep  the 
controller turned on to allow the function operation after the heating season. 

 4. VISIBLE ELEMENTS 

 

1.

 

230 V 50 Hz power cable of the controller 

2.

 

230 V 50 Hz power cable of the central heating pump 

Содержание 12M

Страница 1: ...ather based setting of a heating zone preset temperature Weekly operating schedule Cooperation with a room thermostat Switching the heating off automatically in case of external temperature increase F...

Страница 2: ...es Indicates opening of the mixer Indicates closing of the mixer The symbol is displayed if the mixer is neither being opened nor being closed e g within the hysteresis or during gaps between turning...

Страница 3: ...be installed in a place where the temperature does not exceed 40 C CAUTION Do not immerse the temperature sensors in liquids nor install them at flue gas outlets to the stack INSTALLING TEMPERATURE SE...

Страница 4: ...cores of a 5 m long cable to the connection on the board keeping cable polarization is not necessary Fix the cable in the housing Place the cover and tighten it with two screws Mount the temperature s...

Страница 5: ...f hour If the operating times of heating zone are selected the pump and the mixer operate automatically In the situation when the hourly operating schedule is not selected lack of heat demand the pump...

Страница 6: ...lculates the currently required heating zone temperature Caution Temperatures must meet the condition of T10 C T0 C T 20 C otherwise the control will not work properly Room thermostat Enables switchin...

Страница 7: ...with room thermostat is switched off Automatic operation is switched off or the mean outdoor temperature is lower than the switch off temperature in the case of switched on automatic operation The fee...

Страница 8: ...m Pump switch off Outdoor temperature sensor shortage ALARM WEATHER shortage Activation of an audible alarm The controller operates with the temperature preset for 20 C Outdoor temperature sensor brea...

Страница 9: ...KACZY SKA hereby declares that the type of EUROSTER 12M equipment conforms to the following directives 2014 35 EU LVD 2014 30 EU EMC 2011 65 EU RoHS The complete text of the Declaration of EU conformi...

Страница 10: ...t The attitudes influencing protection of the common good of clean environment are shaped at this level Households are also one of the larger users of small equipment and its rational management at th...

Страница 11: ...exclusively by the manufacturer or by other party clearly authorized by the manufacturer 5 Warranty becomes invalidated in case of any mechanical damage incorrect operation and or making any repairs b...

Отзывы: