EUROSTER 11M – USER MANUAL 

1

 

EUROSTER 11M

 

Operation and assembly manual

 

 

 

MANUFACTURER: P.H.P.U. AS, ul. Polanka 8a/3, 61-131 Poznań 

version of the manual 01.05.2013

 

1.

 

INTRODUCTION 

In  order  to  guarantee  correct  operation  of  central  heating  controller  and  installations  one 
should familiarize oneself with the present user manual. 

2.

 

INTENDED USE 

EUROSTER  11M 

is  a  modern,  microprocessor  controller  for  regulating  temperature  with  the 

use of mixing valve, equipped in limit switches. 
Depending on configuration, it regulates temperature in heating circuit (e.g. floor heating) or 
boiler  return temperature.  It also controls central heating pump operation by switching it off 
when the boiler is damped. 
Temperature is regulated with the use of  PI algorithms (proportional  - integral) which allows 
for fast and accurate regulation for varied loads.  
In temperature regulation mode for the heating circuit, the controller can cooperate with any 
room  regulator  which  has  a  no-voltage  output,  normally  open  (NO)  i.e.  all  EUROSTER 
regulators). 

 

The 

EUROSTER  11Z

  controller  has  been  equipped  in  an  ANTY  STOP  system  to  prevent 

formation  of  deposits  on  motors  of  unused  pumps.  After  finishing  heating  season  it 
automatically  launches  the  mixer  and  the  pumps  every  14  days.  In  order  for  the  system  to 
work out of season, the controller must be left on. 

3.

 

CONTROLLER FUNCTION 

 

keeps constant water temperature: in the central heating circuit or in boiler return 

 

possibility of connecting room regulator 

 

Anty-Stop function to protect pumps and valve against stoppage 

 

frost protection 

 

pump operation test 

 

temperature reading correction 

 
 

Содержание 11M

Страница 1: ...e is regulated with the use of PI algorithms proportional integral which allows for fast and accurate regulation for varied loads In temperature regulation mode for the heating circuit the controller...

Страница 2: ...e a controller with mechanical damage a connection of room regulator only in heating circuit temperature regulation system set 1 The controller can cooperate with any room thermostat with voltage free...

Страница 3: ...and turn clamp box covers g connecting the controller after securing cables against accidental rupture feeder cable should be connected to 230V 50Hz socket with an earthing pin Ambient temperature in...

Страница 4: ...ng factory settings chapter 9 provided for each of the modes Set 1 intended for system with heating medium temperature regulation Set 2 intended for system with return temperature regulation 9 RESTORI...

Страница 5: ...izes regulation dynamics If fast controller reaction to temperature changes is important dynamics should be increased This can however result in over regulation Example reaction of the regulator to su...

Страница 6: ...rection regulated circuit temperature 8 7 0 0 5 5 5 5 C Mixer operation 9 8 1 1 1 2 1 2 1 2 1 2 Pump operation 10 9 1 1 0 3 0 3 1 3 1 3 1 Value calculated by the controller is shown 2 1 means mixer cl...

Страница 7: ...ng Burnt fuse or memory software fault send the device to service Screen and sensor symbol blinking Sh or OP appears Short sensor Short or open sensor OPen check sensor cable for which a symbol is pul...

Страница 8: ...ON OF THE SET 1 sensor with 2 temperature sensors 2 sensor bands 3 rawbolts 4 instructions 5 fixing scheme 18 CONNECTION SCHEME The scheme presented is simplified and does not include all the elements...

Страница 9: ...ed from sales day 2 In case of a complaint the controller together with warranty card should be delivered to sales point 3 A warranty claim will be answered within 14 business days of the date of rece...

Отзывы: