background image

EN50131-1

Grade 2 Compliance

2

x

I n s t a l l a t i o n   M a n u a l

RINS1211-4

EN50131-1

Grade 2 Compliance

2

x

Содержание 10V6.e

Страница 1: ...2x I n s t a l l a t i o n M a n u a l RINS1211 4 EN50131 1 2x...

Страница 2: ......

Страница 3: ...nnections 9 Transformer Battery Connection 9 Keypad Connection 10 Reader Connection 11 Double Pole Alarm Connections 12 Double Pole Tamper Connections 12 DEOL 4K7 Alarm 2K2 Tamper 13 DEOL 4K7 Alarm 4K...

Страница 4: ...put Output Types Not Used Fire Hold Up Any Intruder Any Tamper Any Set Fail Entry Deviation Siren Any Strobe Any Exit Starts Any Final Set Any Strobe Set Fail Keyswitch Unset Entry Exit Lights Restore...

Страница 5: ...0 5V Zone inputs 0 20V normally closed normally open double balanced circuits PGM SAB outputs Switched negative 1Ah max Shared PGM outputs Switched negative 50mA max SAB AUX supply fuses 800mA quick b...

Страница 6: ...nents To Mains Supply Battery Holder 3Ah or 7Ah Battery Cable Entry Holes Wall Fixing Holes Mains Transformer Neutral Live Fuse carrier handle Mains Fuse Anti Surge 315mA Earth Main Cable Entry Hole Z...

Страница 7: ...Supply COM 0V Common SPK Speaker Output 12V 12V Supply STB Output 2 Z7 Input 7 Output 4 BELL Output 3 COM 0V Common TR Siren Tamper Return Z8 Input 8 Output 5 B 0V Z9 Input 9 Output 6 B 12V Supply CO...

Страница 8: ...B Tamper Connection Tamper Spring Z1 COM Z2 COM 12V Z3 COM Z4 Z5 COM Z6 COM 12V Z7 COM Z8 Z9 COM Z10 D1 D2 D3 D4 BAT GND The EURO mini printed circuit board is protected by a metal casing The lid is t...

Страница 9: ...ck Remove for DP Z1 COM Z2 COM 12V Z3 COM Z4 Z5 COM Z6 COM 12V Z7 COM Z8 Z9 COM Z10 D1 D2 D3 D4 BAT GND Transformer Battery Connection The transformer will be factory fitted to the connections shown b...

Страница 10: ...M Z6 COM 12V Z7 COM Z8 Z9 COM Z10 D1 D2 D3 D4 BAT GND Keypad Connection A maximum of 4 keypads may be installed to the EURO mini Each keypad EUR 068 or EUR 069 connects to the RS485 terminal D1 D2 D3...

Страница 11: ...Connection A maximum of 3 readers may be installed to the EURO mini if the EUR 068 is installed Each connect to the RS485 terminal D1 D2 D3 and D4 Each reader must be individually addressed starting...

Страница 12: ...cable wiring W White Blu Blue Terminal Block inside control panel 12V GND 12V GND ALARM TAMPER AUX Input 3 Detector ALARM TAMPER AUX Input 4 Detector ALARM TAMPER AUX Input 5 Detector ALARM TAMPER AUX...

Страница 13: ...T GND If double end of line is used the link above input 1 shown below needs to be closed and specific resistors need to be used depending on which mode is selected see Choose Mode in the programming...

Страница 14: ...3 D4 BAT GND BELL BUS BATTERY AUX Siren 12V Supply 0V Bell Tamper Bell Trigger Strobe Trigger PGM AUX SPK STB BELL TR B B BELL BUS BATTERY AUX 1 or 2 16ohm speakers may be wired in parallel PGM AUX SP...

Страница 15: ...m are negative applied and cannot be altered The example below shows how to connect a typical 12V dialler BELL BUS BATTERY AUX 12V GND PGM AUX SPK STB BELL TR B B 1 2 3 4 5 0v 12V Example Auto Dialler...

Страница 16: ...led to PD6662 AMD2 at security grade 1 or 2X and environmental class 2 This product is sold subject to our standard warranty conditions and is warranted against defects in workmanship for a period of...

Страница 17: ...Castle Care Tech Page 17 Input Table Appendix Input Number Input Type Input Areas Description 1 2 3 4 5 6 7 8 9 10...

Страница 18: ...Page 18 Castle Care Tech...

Страница 19: ...Castle Care Tech Page 19...

Страница 20: ...Tech Ltd First Floor 6 Bracknell Beeches Old Bracknell Lane West Bracknell Berkshire RG12 7BW Helpdesk 01344 469499 Opening Hours 7 00am 7 30pm Monday to Friday E mail support castle caretech com Webs...

Отзывы: