– Position the product in the room centre to ensure
optimum air circulation.
– Do not position the product close to radiators or
other heat sources.
– Keep window and doors closed in rooms to be
dehumidified.
– Avoid repeatedly entering and leaving rooms to
be dehumidified.
– The product is intended for room temperatures of
5–35 °C.
– Leave the product to stabilise for a few minutes
after installation.
Operation
Check before switching on!
Check the safe condition of the product:
– Check whether there are any visible defects.
– Check whether the condensate tank is empty.
– Ensure that the condensate tank is correctly
inserted.
Functions
The product operates according to the condensation
principle.
•
The fan sucks in the humid room air through the
intake filter.
•
The room air is cooled to below the dew point and
the water vapour contained in the air precipitates
as condensate.
•
The dehumidified, cooled air is then warmed
back up and blown out again at a temperature a
few degrees above room temperature.
•
When the unit is plugged in, it will indicate the
room humidity level.
•
When you set the humidity, it will indicate the
humidity that you have selected
•
When you program the time for the unit to turn on
and off, it will show the hours.
•
When the environment humidity is lower than
35%, it will show
[35]
•
When the environment humidity is higher than
95%, it will show
[95]
Operating Instructions
•
The Power indication light will turn on when the
unit is plugged in, regardless of whether the unit
is operating or not.
– Press
[ ]
to turn on or turn off the unit.
– Press
[
]
button as follows:
– Press to set the desired fan speed. It can be
adjusted between high speed and low speed.
– Press
[
]
button to set the desired humidity level
in the room, which can be set from 40% to 80%
at 5% intervals.
– After a period of working, when environment
humidity is lower than the selected humidity by
2%, compressor will be shut off automatically but
the fan will operate for few more minutes; When
environment humidity is equal to or higher than
the selected humidity by 2%, the compressor will
restart once 3-minute delay compressor protec-
tion expires.
– Press
[
]
button to set the timer
– Press the button to set the time when the unit
turns on and turns off. If you want to cancel the
timer programming, press the button to adjust the
time to
[00]
, and press the button again.
– The timer can be set up to 24 hours at an hour
interval. To set the time from which the machine
will be on, please make sure the machine is
plugged in, and then press the button to set the
time from when you want to turn it on.
– To set the time when the machine will be off,
please make sure the machine is operating, and
then press the button to set the time when you
want to turn it off.
Draining The Collected Water
When the drainage tank is full, the tank full indicator
light will turn on, the operation will stop automatically
and the buzzer will beep 15 times to alert the user,
that the water need to be emptied from the drainage
tank.
Emptying the Drainage Tank
– Lightly press on the sides of the tank with both
hands and pull the tank out gently.
– Discard the collected water
Note
•
Do not remove the float from the water tank. The
water full sensor will no longer be able to detect
the water level correctly without the float and
water may leak from the water tank.
•
If the drainage tank is dirty, wash it with cold or
lukewarm water. Do not use detergent, scouring
pads, chemically treated dust cloths, gasoline,
benzene, thinner, or other solvents, as these can
scratch and damage the tank and cause water
leakage
•
When replacing the drainage tank, press the tank
firmly into place with both hands. If the tank is not
positioned properly, the
[TANK FULL]
sensor will
be activated, and the dehumidifier will not oper-
ate.
Continuous Water Drainage
DANGER! Risk of injury!
The product
may only be put into operation if no faults
are found during the check-up. It is crucial
that any defective parts are replaced before
the product is used again.
Note:
At room temperatures below 5 °C
and a relative humidity below 35%, eco-
nomic product output is no longer guaran-
teed.
The indicator features 3 functions:
Содержание LEF-200-40
Страница 1: ...LEF 200 40 107597 DE Luftentfeuchter GB Dehumidifier PL Osuszacz powietrza...
Страница 2: ...2 bersicht Overview Przegl d Inbetriebnahme Commissioning Uruchomienie 1 2...
Страница 3: ...3 1...
Страница 4: ...4 Bedienung Operation Obs uga 1 2 3 4...
Страница 5: ...5 Wartung Maintenance Konserwacja 5 1 2...
Страница 22: ...22...
Страница 23: ...23...