00053102.DOC, Version 1.1
10/10
CLEANING AND MAINTENANCE
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
The lens has to be replaced when it is obviously damaged,
so that its function is impaired, e. g. due to cracks or deep scratches!
CAUTION!
There are no serviceable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
Should you need any spare parts, please use genuine parts.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
230 V AC, 50 Hz ~
via included 12 V AC, 1000 mA power unit
Power consumption:
max. 13 W
Number of LEDs:
3 x 40
Protection grade spot:
Protection grade power unit:
IP 68
IP 44
Dimensions spot (DxH):
88 x 88 mm
Weight set:
2.4 kg
Maximum ambient temperature T
a
:
45° C
Maximum housing temperature T
B
(steady state):
65° C
Min. distance from flammable surfaces:
0.5 m
Min. distance to lighted object:
0.1 m
Please note: Every information is subject to change without prior notice. 14.09.2010 ©