51786500_V_1_1.DOC
24/63
INSTALLATION
Installing/Replacing the lamp
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
For the installation, you need one EHJ 24 V/250 W G-6.35 lamp.
The lamp has to be replaced when it is damaged
or deformed due to the heat!
CAUTION!
During the operation, the lamp reaches temperatures of up to 600° C.
Before replacing the lamp, unplug mains
lead and let the lamp cool down (approx. 10
minutes).
During the installation do not touch the glass-
bulbs bare-handed! Please follow the lamp
manufacturer's notes!
Do not install lamps with a higher wattage!
Lamps with a higher wattage generate
temperatures the device was not designed for.
Damages caused by non-observance are not
subject to warranty.
Procedure:
Step 1:
Unscrew the fixation screws X, Y of the lamp system and carefully remove it from the housing.
Step 2:
If replacing the lamp, remove the old lamp from the lamp holder.
Step 3:
Insert the lamp into the lamp holder.
Step 4:
Replace the lamp system in the housing and tighten the fixation screws.
Step 5:
Adjust the lamp as described under lamp adjustment.
Do not operate this device with opened cover!