52201070_V_1_0_4946.DOC
14/25
Should you have further questions, please contact your dealer.
Replacing the lamp
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
CAUTION!
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need one U-shaped flash-tube.
Procedure:
Step 1:
Unscrew the protective shield counter clockwise. Leave the security chain intact.
Step 2:
Remove the protective shield.
Step 3:
Remove the old lamp from the lamp-socket.
Step 4:
Insert the new U-shaped flash-tube into the lamp-socket.
Step 5:
Replace the protective shield and screw it clockwise back in place
Do not operate this device with opened protective shield!
TECHNICAL SPECIFICATIONS
Power supply:
230 V/50 Hz
Power consumption:
45 W
Dimensions (LxWxH):
160 x 160 x 170 mm
Weight:
0.5 kg
Maximum ambient temperature t
a
:
45° C
Maximum housing temperature t
B
(steady state):
80° C
Lamp:
Article Number:
OMNILUX 230V/45W stroboscope lamp U-shape
85010145