13
3) All carrying parts have to be inspected on damages or material fatigue.
4) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
5) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
6) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
7) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
Maintenance and service operations are only to be carried out by authorized dealers.
Should you need any spare parts, please use genuine parts.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Max. carrying capacity/stand:
18 kg
Max. carrying capacity/complete system:
25 kg
Minimum height:
1.7 m
Maximum height:
2.8 m
Maximum elevation:
1.1 m
Weight/stand:
7.5 kg
Weight/cross section:
10.5 kg
Weight/complete system:
21 kg
Please note: Every information is subject to change without prior notice. 07/02 ©