00136213.DOCX, Version 1.0
15/16
5.1 Connection with the mains
Connect the device to the mains with the CEE plug. The earth has to be connected! If the device will be
directly connected with the local power supply network, a disconnection switch with a minimum opening of 3
mm at every pole has to be included in the permanent electrical installation.
5.2 Outputs
Output is via eight safety sockets and four 16 A three-phase current output sockets. Connect your loads via
the output sockets. Please note that the maximum current must never be exceeded.
6. OPERATION
The device includes a multimeter for measuring current, voltage and frequency.
Operating button:
Button
Function
⊳
Switch display between phase L1, L2 and L
Measuring current
In the first three lines, the values for the current phases A, B and C are indicated.
Measuring voltage
In the fourth line, the voltage of the set phase or line voltage is indicated. Use the button
⊳
to switch
between the phase voltages U
A
, U
B
and U
C
as well as the line voltages U
AB
, U
BC
and U
CA.
The indicator LEDs
of the respective phases (L1, L2, L3) light up.
Measuring frequency
In the lower line, the measured frequency value is indicated.
7. CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tightly connected and must not
be corroded.
2) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered to by a
skilled installer and any safety problems have to be removed.