Replacing the fuse
If the lamp burns out, the fine-wire fuse of the device might fuse, too. Only replace the fuse by a fuse of same
type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1:
Unscrew the fuseholder on the rearpanel with a fitting screwdriver from the housing (anti-
clockwise).
Step 2:
Remove the old fuse from the fuseholder.
Step 3:
Install the new fuse in the fuseholder.
Step 4:
Replace the fuseholder in the housing and fix it.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device will be damaged (cable firmly connected with the device), it has to be
replaced by authorized dealers only in order to avoid hazards.
If the power supply cable of this device will be damaged (replaceable cable), it has to be replaced by a
special power supply cable available at your dealer.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
230 V AC, 50 Hz ~
Power consumption:
350 W
Sound-control:
via built-in microphone
Dimensions (LxWxH):
280 x 220 x 160 mm
Weight:
3 kg
Fitting lamp:
230 V/300 W G-6.35
Maximum ambient temperature t
a
:
45° C
Maximum housing temperature t
B
(steady state):
90° C
Fitting fuse:
F 2 A, 250 V
Please note: All specifications are subject to change withour prior notice.
6/00
©
Errors and omissions excepted.