00110746, Version 1.1
27/36
Screw a clamp via a M10 screw and self-locking nut onto the Omega-holder.
Insert the screw of the Omega-holder into the respective holes on the bottom of the device. Tighten the
screws fully with a hexagon key.
Lead the safety bond through the Omega-holder of the device and over the trussing system or a safe fixation
spot. Insert the end in the quick link and tighten the safety screw.
The maximum drop distance must never exceed 20 cm.
A safety bond which already hold the strain of a crash or which is defective must not be used again.
DMX512 control
The wires must not come into contact with each other, otherwise
the devices will not work at all, or will not work properly.
Please note, the starting address depends upon which controller is being used.
DMX-512 Controller
120 Ohms
Device 3
Starting address 33
DMX OUT
DMX IN
100-240 V
AC
POWER IN
50/60 Hz
FUSE
F2A/250V
1: Ground
2: Signal (–)
3: Signal (+)
Device 2
Starting address 17
DMX OUT
DMX IN
100-240 V
AC
POWER IN
50/60 Hz
FUSE
F2A/250V
1: Ground
2: Signal (–)
3: Signal (+)
Device 1
Starting address 1
DMX OUT
DMX IN
100-240 V
AC
POWER IN
50/60 Hz
FUSE
F2A/250V
1: Ground
2: Signal (–)
3: Signal (+)
Only use a DMX cable and 3-pin XLR plugs and connectors in order to connect the controller with the fixture
or one fixture with another.
Occupation of the XLR connection:
If you are using controllers with this occupation, you can connect the DMX output of the controller directly
with the DMX input of the first device in the DMX chain. If you wish to connect DMX controllers with other
XLR outputs, you need to use adapter cables.
Building a serial DMX chain:
Connect the DMX output of the first device in the DMX chain with the DMX input of the next device. Always
connect one output with the input of the next device until all devices are connected.
Содержание LED TMH-51
Страница 1: ......