background image

 

00119586, Version 1.1 

 

18/28

- - -m

Warning – risk of burns and fire 
• 

The admissible ambient temperature range (Ta) is -5 to  +45°C. Do not operate  the  device outside of this 
temperature range. 

• 

The housing temperature (Tc) can be up to 60°C during use. Avoid contact by persons and materials. 

• 

Do not illuminate surfaces within 10 cm of the device. This value is indicated on the device by the       
symbol. 

• 

Do  not  use  the  device  near  highly  flammable  materials.  Always  place  the  device  at  a  location  where 
sufficient air circulation is ensured. Leave 50 cm of free space around the device. Never cover the air vents 
of the housing. 

 

Warning – risk of injuries  
• 

Do  not  look  directly  at  the  light  source.  Persons  with  light-sensitive  epilepsy  may  suffer  from  epileptic 
seizures or fall unconscious. 

• 

Make  sure  that  the  product  is  set  up  or  installed  safely  and  expertly  and  prevented  from  falling  down. 
Comply with the standards and rules that apply in your country, in particular EN 60598-2-17. 

• 

If you lack the qualification, do not attempt the installation yourself, but instead use a professional installer. 
Improper installation can result in bodily injury and or damage to property. 

• 

The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety 
precautions. 

• 

For overhead use, always secure the device with a secondary safety attachment such as a safety bond or 
safety net. 

• 

Make  sure  that  the  area  below  the  installation  place  is  blocked  when  rigging,  derigging  or  servicing  the 
device. 

• 

For  commercial  use  the  country-specific  accident  prevention  regulations  of  the  government  safety 
organization for electrical facilities must be complied with at all times. 

 

Caution – material damage 
• 

This device must not be connected to the mains voltage by means of a dimmer. 

• 

Lighting effects are not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

• 

Never  switch  the  device  on  and  off  at  short  intervals.  This  will  considerably  reduce  the  service  life  of  the 
device. 

• 

If  the  device  has  been  exposed  to  drastic  temperature  fluctuation,  do  not  switch  it  on  immediately.  The 
resulting  condensation  may  destroy  the  device.  Allow  the  device  to  reach  room  temperature  before 
connecting it. Wait until the condensation has evaporated. 

• 

Please  use  the  original  packaging  to  protect  the  device  against  vibration,  dust  and  moisture  during 
transportation or storage. 

• 

If a serial number label is affixed to the device, do not remove the label as this would make the guarantee 
void. 

 

 

 

Содержание LED Super Strobe ABL

Страница 1: ......

Страница 2: ...es 16 SAFETY INSTRUCTIONS 17 DESCRIPTION OF THE DEVICE 19 INSTALLATION 20 CONNECTIONS 20 DMX512 control 20 Connection to the mains 20 Power supply of further devices 21 OPERATION 21 Men struktur 21 St...

Страница 3: ...ung im Internet herunter laden EINF HRUNG Wir freuen uns dass Sie sich f r eines unserer Produkte entschieden haben Wenn Sie nachfolgende Hinweise beachten sind wir sicher dass Sie lange Zeit Freude a...

Страница 4: ...enutzers f hren Die Steckdose muss gut zug nglich sein damit Sie im Bedarfsfall den Netzstecker schnell ziehen k nnen Fassen Sie den Netzstecker niemals mit nassen H nden an da die Gefahr eines Stroms...

Страница 5: ...tzungen und oder zur Besch digung von Eigentum f hren Der Hersteller haftet nicht f r Sch den die durch unsachgem e Installation und unzureichende Sicher heitsvorkehrungen verursacht werden Bei einer...

Страница 6: ...ausgelegt sein 2 Sperren Sie den Arbeitsbereich w hrend der Montage und arbeiten Sie von einer stabilen Plattform aus 3 Verwenden Sie Montagematerial das f r die Struktur geeignet ist und die Last des...

Страница 7: ...rkers verst rkt werden um eine fehlerfreie Daten bertragung zu gew hrleisten Belegung der XLR Verbindung Anschluss ans Netz Das Ger t verf gt ber ein Schaltnetzteil das eine Netzspannung zwischen 100...

Страница 8: ...Version Standalone Betrieb Master Slave Betrieb mit mehreren Ger ten Es lassen sich mehrere Ger te zusammenschalten max 32 Das Hauptger t Master kann dann alle Nebenger te Slave synchron steuern ohne...

Страница 9: ...2 Protokoll verf gt das Ger t ber 148 Steuerkan le Es kann aber auch in einen Modus mit 7 13 oder 22 Kan len umgeschaltet werden wenn andere Funktionen ben tigt werden Damit das Ger t vom Controller a...

Страница 10: ...onen im DMX Betrieb 7 Kanal Modus Kanal Wert Funktion 1 Dimmer SMD 5730 000 255 Gesamthelligkeit 0 100 2 Strobe SMD 5730 000 008 Keine Funktion 009 255 Strobe mit zunehmender Geschwindigkeit 0 100 3 D...

Страница 11: ...tomatik Programm 16 Effekte SMD 5050 000 007 Keine Funktion 008 022 Programm 1 023 037 Programm 2 038 052 Programm 3 053 082 Programm 4 083 097 Programm 5 098 112 Programm 6 113 127 Programm 7 128 142...

Страница 12: ...000 255 Gr n 0 100 8 SMD 5050 000 255 Blau 0 100 9 SMD 5050 000 255 Rot 0 100 Segment 2 10 SMD 5050 000 255 Gr n 0 100 11 SMD 5050 000 255 Blau 0 100 12 SMD 5050 000 255 Rot 0 100 Segment 3 13 SMD 505...

Страница 13: ...al Wert Funktion LED Gruppe 1 Dimmer SMD 5730 000 255 Gesamthelligkeit 0 100 2 Strobe SMD 5730 000 008 Keine Funktion 009 255 Strobe mit zunehmender Geschwindigkeit 0 100 3 Dimmer SMD 5050 000 255 Ges...

Страница 14: ...autorisierten Fachhandel vorbehalten Sollten einmal Ersatzteile ben tigt werden verwenden Sie bitte nur Originalersatzteile Sollten Sie noch weitere Fragen haben wenden Sie sich bitte an Ihren Fachh n...

Страница 15: ...imale Umgebungstemperatur Ta 45 C Max Leuchtentemperatur im Beharrungszustand Tc 60 C Mindestabstand zu entflammbaren Oberfl chen 0 5 m Mindestabstand zum angestrahlten Objekt 0 1 m Gewicht 3 5 kg Zub...

Страница 16: ...TRODUCTION Thank you for having chosen one of our products If you follow the instructions given in this manual we are sure that you will enjoy this device for a long period of time Product features 3i...

Страница 17: ...you can unplug the device quickly if need be Never touch the mains plug with wet or damp hands There is the risk of potentially fatal electric shock The mains cable must not be bent or squeezed Keep i...

Страница 18: ...t be made liable for damages caused by incorrect installations or insufficient safety precautions For overhead use always secure the device with a secondary safety attachment such as a safety bond or...

Страница 19: ...CRIPTION OF THE DEVICE 1 Fixation screw 2 Mounting bracket 3 SMD 5050 RGB LEDs 4 SMD 5730 CW LEDs 5 DMX input 6 DMX output 7 Fuse 8 Power feed through output 9 Power input 10 LED display and operating...

Страница 20: ...maximum drop distance of the device will not exceed 20 cm 5 To align the device release the fixation screws at the mounting bracket adjust the desired inclination angle and tighten the fixation screw...

Страница 21: ...LNA Master Slave mode Sound control SoUn So 0 16 Program 0 16 SE 00 99 Microphone sensitivity low high Automatic mode Auto Au 0 16 Program 0 16 SP 00 99 Program running speed slow fast LED LED ON OFF...

Страница 22: ...on you can to turn the display upside down DMX operation Setting the number of DMX channels and the DMX starting address For operation with a controller with DMX512 protocol the device is equipped wit...

Страница 23: ...Functions in DMX mode 7 channel mode Channel Value Function 1 Dimmer SMD 5730 000 255 Total brightness 0 100 2 Strobe SMD 5730 000 008 No function 009 255 Strobe effect with increasing speed 0 100 3 D...

Страница 24: ...matic programs 16 effects SMD 5050 000 007 No function 008 022 Program 1 023 037 Program 2 038 052 Program 3 053 082 Program 4 083 097 Program 5 098 112 Program 6 113 127 Program 7 128 142 Program 8 1...

Страница 25: ...100 Segment 2 10 SMD 5050 000 255 Green 0 100 11 SMD 5050 000 255 Blue 0 100 12 SMD 5050 000 255 Red 0 100 Segment 3 13 SMD 5050 000 255 Green 0 100 14 SMD 5050 000 255 Blue 0 100 15 SMD 5050 000 255...

Страница 26: ...l brightness 0 100 2 Strobe SMD 5730 000 008 No function 009 255 Strobe effect with increasing speed 0 100 3 Dimmer SMD 5050 000 255 Total brightness 0 100 4 Strobe SMD 5050 000 008 No function 009 25...

Страница 27: ...or local authorities for more information Remove any inserted batteries and dispose of them separately from the product You as the end user are required by law Battery Ordinance to return all used bat...

Страница 28: ...Eurolite is a brand of Steinigke Showtechnic GmbH Andreas Bauer Str 5 97297 Waldb ttelbrunn Germany D00110564 Version 1 0 Publ 25 03 2019...

Отзывы: