ATTACHMENT
The device may be placed on the floor by unfolding the brackets or mounted to the wall or ceiling via one of
the brackets. Always choose screws and plugs which are suitable for use in your wall/ceiling and have
enough holding power. Fasten the device in such way that it will not fall down.
CONNECTIONS
DMX512 control
A DMX512 data link is required in order to control the device via DMX. The device provides 3-pin XLR
connectors for DMX connection.
1 Connect the output of your DMX controller to the DMX input DMX IN of the device with a DMX cable.
2 Connect the DMX output DMX OUT of the light set to the DMX input of the next unit in the chain. Always
connect one output to the input of the next unit until all units are connected.
3 At the last unit, the DMX cable has to be terminated. Plug the terminator with a 120 Ω resistor between
Signal (–) and Signal (+) in the DMX output of the last unit.
4 If the cable length exceeds 300 m or the number of DMX devices is greater than 32, it is recommended
to insert a DMX level amplifier to ensure proper data transmission.
XLR connection:
Connection with the mains
Connect the device to the mains with the power plug.
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.