00093995.DOC, Version 1.0
10/11
For outdoor use, the installer must always make sure to connect a rubber cable H05RN-F or HO5RR-F. For
installations in the ground, an underground power cable NYY must be used!
All valid instructions concerning the installation of cables outdoors or in the ground must be adhered!
The ambient temperature must always be between -5° C and +45° C. Keep away from direct insulation
(particularly in cars) and heaters.
The maximum relative humidity is 100 % with an ambient temperature of 25° C.
This device must only be operated in an altitude between -20 and 2000 m over NN.
Do not shake the device. Avoid brute force when installing or operating the device.
When choosing the installation spot, please make sure that there are no cables lying around. You endanger
your own and the safety of others!
This luminaire must never be covered. Danger of burning!
The symbol
- - -m
determines the minimum distance from lighted objects. The minimum distance
between light-output and the illuminated surface must be more than the given value.
The maximum ambient temperature T
a
must never be exceeded.
Never use solvents or aggressive detergents in order to clean the device! Rather use a soft and damp cloth.
Please use the original packaging if the device is to be transported.
Please consider that unauthorized modifications on the device are forbidden due to safety reasons!
If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, lamp explosion, etc.
INSTALLATION
Unpack the Landscape Spot.
Mount the Landscape Spot onto the stake.
Install the spot at the desired installation spot and set the inclination angle.
Connection with the mains
Connect the device to the mains with the power plug.
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
OPERATION
Connect the device to the mains with the power-plug. Make sure that the outlet is in a dry area. After you
connected the device to the mains, the Landscape Spot starts running.