00066535.DOC, Version 1.0
24/24
Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1:
Open the fuseholder on the rear panel with a fitting screwdriver.
Step 2:
Remove the old fuse from the fuseholder.
Step 3:
Install the new fuse in the fuseholder.
Step 4:
Replace the fuseholder in the housing.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by a special power supply
cable available at your dealer.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
230 V AC, 50 Hz ~
Power consumption:
17 W/30 VA
Number of DMX channels:
2/10
DMX512 connection:
3-pin XLR
Sound-control:
via built-in microphone
Maximum ambient temperature T
a
:
45° C
Maximum housing temperature T
C
(steady state):
50° C
Min. distance from flammable surfaces:
0.5 m
Min. distance to lighted object:
0.1 m
Fuse:
T 1 A, 250 V
LED type:
5mm-RGBAW / SMD-white
Number of LEDs:
256 / 108
Beam angle:
15°
Mounting hole:
D = 36 mm
Dimensions (LxWxH):
800 x 210 x 90 mm
Weight:
6 kg
Accessories:
No.
EUROLITE RC-2 remote control 10m
51918558
EUROLITE TH-50S Theatre hook, black
58000651
Saveking Safety bond 3x600 black
58010252
Please note: Every information is subject to change without prior notice. 08.03.2012 ©