00054421.DOC, Version 1.0
25/28
Connection with the mains
DANGER TO LIFE!
The electric connection must only be carried out by a qualified electrician!
In order to connect the device to the mains, you have to install a power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Connect the device to the mains with the power-plug.
Lighting effects must not be connected to dimming-packs.
OPERATION
With the power switch, you can switch the device on and off.
After you connected the effect to the mains, the SL-575C starts running. During the Reset, the motors are
trimmed and the device is ready for use within approximately 20 seconds.
Move the objective-lens for adjusting the focus in order to obtain a sharp projection.
Stand Alone operation
In the Stand Alone mode, the SL-575C can be used without DMX-controller.
Disconnect the SL-575C from the DMX-controller and set all DIP-switches to Off.
DMX-controlled operation
You can control the devices individually via your DMX-controller. Every DMX-channel has a different
occupation with different features.