EuroLite AKKU UP-7 QCL Spot QuickDMX Скачать руководство пользователя страница 22

 

00128199, Version 1.0 

22/40

 

 

Содержание AKKU UP-7 QCL Spot QuickDMX

Страница 1: ......

Страница 2: ...Via QuickDMX 9 ANWENDUNGEN 10 bertragung 1 1 10 bertragung 1 Mehrere 10 Parallel bertragung 10 NETZANSCHLUSS 11 Akkubetrieb 11 Ladezustand 11 BEDIENUNG 12 Standalone Modus 12 Master Slave Betrieb 12...

Страница 3: ...status 29 OPERATION 30 Stand alone mode 30 Master slave operation 30 Master Slave operation via QuickDMX 30 EUROLITE IR 35 remote control 33 DMX controlled operation 34 Addressing 34 DMX Protocol 35 C...

Страница 4: ...00128199 Version 1 0 4 40...

Страница 5: ...und QuickDMX Transceiver Frostfilter und IR Fernbedienung 7 leistungsstarke 8 W RGBW LEDs 4in1 Mit integriertem QuickDMX Funksender empf nger f r die drahtlose bertragung von DMX512 Signalen Kompakt...

Страница 6: ...rtende Teile Schlie en Sie das Ger t nur an eine vorschriftsm ig installierte Steckdose an deren Spannung und Frequenz mit dem Typenschild des Ger ts genau bereinstimmt und die ber einen Fehlerstromsc...

Страница 7: ...ktrische Anlagen und Betriebsmittel unbedingt zu beachten Vorsicht Sachsch den Schlie en Sie das Ger t niemals ber einen Dimmer an die Netzspannung an Lichteffekte sind generell nicht f r den Dauerbet...

Страница 8: ...elschrauben 7 L ftungsschlitze 8 Klappfu Feststellschraube 9 Klappfu 10 Gummifu 11 Kensington Sicherheitsanschluss 12 3 poliger DMX Eingang 13 3 poliger DMX Ausgang 14 Spannungsversorgungs eingang 15...

Страница 9: ...s mit dem DMX Eingang des n chsten Ger ts in der Kette Verbinden Sie immer einen Ausgang mit dem Eingang des n chsten Ger ts bis alle Ger te angeschlossen sind 3 Am letzten Ger t muss die DMX Leitung...

Страница 10: ...tromverbrauch zu vermeiden ANWENDUNGEN Einem Sender lassen sich mehrere Empf nger zuweisen Es k nnen maximal 512 Empf nger betrieben werden bertragung 1 1 Das DMX Signal wird bei einem Sender eingespe...

Страница 11: ...kku Betriebszeit h ngt vom Betriebsmodus und der Umgebungstemperatur ab maximal 17 Stunden Schalten Sie das Ger t nach dem Betrieb mit dem Netzschalter aus 2 Zum Aufladen des Akkus schlie en Sie das G...

Страница 12: ...e m ssen auf die jeweilige Betriebsart eingestellt werden 1 Stellen Sie beim Master Ger t den Modus Master ein und bei allen Slave Ger ten den Modus Slave ein Bitte beachten Sie weitere Hinweise unter...

Страница 13: ...mit den zuvor eingestellten Werten Vorgabewerte fett gedruckt MAIN Level Menu Level Beschreibung DMX Addr 001 512 Einstellen der DMX Startadresse DMX Chan 3 CH 4 CH 6CH 8CH 11CH Ausw hlen des DMX Kan...

Страница 14: ...ite Bal Red 125 255 Wei abgleich Vorgabewert RGBW 255 Green 125 255 Blue 125 255 White 125 255 Sys Info Temperat xxC Innentemperatur des Ger tes Cur Power xxx Verbliebene Akkuleistung in Prozent Econo...

Страница 15: ...e im Halter nach oben zeigt Entnehmen Sie vorsichtshalber die Batterie aus der Fernbedienung bei l ngerem Nichtgebrauch OFF _ FADE COLOR STROBE ON Pty1 Pty2 Pty3 Pty4 CC Tasten Funktion Steuerung ber...

Страница 16: ...ale vom Controller reagiert Die Startadresse ist abh ngig von Ihrem DMX Controller Lesen Sie hierzu die Dokumentation des Ger ts Wenn Sie die Startadresse im 11 Kanal Modus z B auf 12 definieren beleg...

Страница 17: ...ine Funktion Strobe Effekt mit zunehmender Geschwindigkeit 8 Kanal Modus Kanal Wert Eigenschaft 1 0 255 Dimmer Dimmerintensit t von 0 bis 100 2 0 255 Rot 0 100 zunehmend 3 0 255 Gr n 0 100 zunehmend 4...

Страница 18: ...ergeschwindigkeit Sprungantwort Dimmergeschwindigkeit aus Control Board Einstellung OFF Ansprechverhalten von LEDs Dim1 Ansprechverhalten von Halogenlampen schnell Dim2 Ansprechverhalten von Halogenla...

Страница 19: ...h use nicht Unternehmen Sie keine Reparaturversuche da dies ein Sicherheitsrisiko darstellt Wartungs und Servicearbeiten sind ausschlie lich dem autorisierten Fachhandel vorbehalten Sollten einmal Ers...

Страница 20: ...zrate 1 23 Hz DMX Kan le 3 4 6 8 11 DMX Eingang 1 x 3 pol XLR M Einbauversion DMX Ausgang 1 x 3 pol XLR W Einbauversion L fter Ohne da konvektionsgek hlt Ansteuerung IR Fernbedienung QuickDMX eingebau...

Страница 21: ...541 EUROLITE DMX Kabel XLR 3pol 5m sw Best Nr 3022785K PSSO DMX Kabel XLR 3pol 5m sw Neutrik Best Nr 30227812 PSSO PowerCon Verbindungskabel 3x1 5 5m Best Nr 30235040 SOMMER CABLE Kombikabel DMX Power...

Страница 22: ...00128199 Version 1 0 22 40...

Страница 23: ...mote control 7 high power 8 W RGBW LEDs 4in1 With integrated QuickDMX transmitter receiver for the wireless transmission of DMX512 signals Compact and bright Additional frost filter provides a soft ho...

Страница 24: ...ctive ground Never deactivate the protective ground of a mains cable Failure to do so could possibly injure the user The mains outlet must be easily accessible so that you can unplug the device quickl...

Страница 25: ...h the device on and off in short intervals This will considerably reduce the service life of the device If the device has been exposed to drastic temperature fluctuation do not switch it on immediatel...

Страница 26: ...the frost filter via knurled screws 7 Ventilation slots 8 Folding foot fixation screw 9 Folding foot 10 Rubber foot 11 Kensington security slot 12 3 pin DMX input 13 3 pin DMX output 14 Power input 15...

Страница 27: ...utput DMX OUT of the light set to the DMX input of the next unit in the chain Always connect one output to the input of the next unit until all units are connected 3 At the last unit the DMX cable has...

Страница 28: ...operation disconnect the power supply cable from the mains outlet to prevent unnecessary power consumption USE Several receivers may be assigned to a transmitter It is possible to operate a maximum o...

Страница 29: ...s on the operating mode and the ambient temperature max 17 hours After the operation switch the device off 2 For charging the battery connect the device to a power outlet via the enclosed power unit C...

Страница 30: ...perating modes 1 Set the master device to the mode Master Set the slave mode Slave on every slave device Please refer to the instructions under Control Board 2 Connect the DMX output of the master uni...

Страница 31: ...ption DMX Addr 001 512 DMX address setting DMX Chan 3 CH 4 CH 6CH 8CH 11CH Setting DMX channel mode Dimmer OFF Dim1 Dim2 Dim3 Dim4 Dimmer speed step response OFF Response characteristics of LEDs Dim1...

Страница 32: ...sensitivity White Bal Red 125 255 White balance Default setting RGBW 255 Green 125 255 Blue 125 255 White 125 255 Sys Info Temperat xxC Internal temperature of the device Cur Power xxx Remaining batt...

Страница 33: ...mote control as a precaution if the device is not used for a longer period of time Buttons Function IR remote control onoff Dimmer intensity of the LED colors stepless RGBW color mixture brightness wi...

Страница 34: ...ntroller The starting address depends upon which DMX controller is being used Please refer to the controller s documentation If you set for example the address in the 11 channel mode to channel 12 the...

Страница 35: ...No function Sound control No function Strobe effect with increasing speed 8 channel mode Channel Value Feature 1 0 255 Dimmer dimmer intensity from 0 to 100 2 0 255 Red 0 100 increasing 3 0 255 Green...

Страница 36: ...Control Board setting dimmer speed OFF Response characteristics of LEDs Dim1 Response characteristics of halogen lamps fast Dim2 Response characteristics of halogen lamps less fast Dim3 Response char...

Страница 37: ...not try to repair the device by yourself as this may result in damage Maintenance and service operations are only to be carried out by authorized dealers Should you need any spare parts please use ge...

Страница 38: ...homogenous color mix Flash rate 1 23 Hz DMX channels 3 4 6 8 11 DMX input 1 x 3 pin XLR M mounting version DMX output 1 x 3 pin XLR F mounting version Cooling fan No cooling by convection Control IR...

Страница 39: ...kDMX No 41700541 EUROLITE DMX cable XLR 3pin 5m bk No 3022785K PSSO DMX cable XLR 3pin 5m bk Neutrik No 30227812 PSSO PowerCon Connection Cable 3x1 5 5m No 30235040 SOMMER CABLE Combi Cable DMX PowerC...

Страница 40: ...Eurolite is a brand of Steinigke Showtechnic GmbH Andreas Bauer Str 5 97297 Waldb ttelbrunn Germany D00125583 Version 1 0 Publ 09 03 2020...

Отзывы: