00113517, Version 1.0
31/44
DMX-512 connection / connection between fixtures
DMX-512 Controller
120 Ohms
Device 1
Starting address 1
Device 1
Starting address 1
Device 2
Starting address11
Device 2
Starting address11
Device 3
Starting address 21
Device 3
Starting address 21
The wires must not come into contact with each other, otherwise
the fixtures will not work at all, or will not work properly.
Please note, the starting address depends upon which controller is being used.
Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with
the fixture or one fixture with another.
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always
connect one output with the input of the next fixture until all fixtures are connected.
Caution:
At the last fixture, the DMX-cable has to be terminated. Plug the terminator with a 120
resistor
between Signal (–) and Signal (+) in the DMX-output of the last fixture.
The DMX connection can be made via DMX adapters or special DMX connection cables. The important thing
about this is that the connection is always sufficiently isolated against humidity.
Master/Slave operation
The master/slave operation enables that several devices can be synchronized and controlled by one master