3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
There are no serviceable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
Should you need any spare parts, please use genuine parts.
Observe prescribed testing deadlines:
1. Once a year by an expert
2. Every four years by a skilled person
3. Before every use for breakage and function by the operator
Should you have further questions, please contact your dealer.
8. TECHNICAL SPECIFICATIONS
Power supply:
230 V AC, 50 Hz ~
Max. power output:
21600 W
Max. total current:
96 A
Max. output/channel:
3680 W
Max. current/channel:
16 A
Max. load per fixation point:
5 kg
Max. spaced braceload:
30 kg
Max. centered braceload:
25 kg
Dimensions (LxWxH):
2000 x 195 x 40 mm
Weight:
4 kg
Max. service life:
10 years
Please note: Every information is subject to change without prior notice. 05.01.2005 ©