EuroLite 42109605 Скачать руководство пользователя страница 23

 

00091417.DOCX, Version 1.0 

23/40

Please make sure that there are no obvious transport damages. Should you notice any damages on the A/C 
connection cable or on the casing, do not take the device into operation and immediately consult your local 
dealer. 
 
This device falls under protection-class I. The power plug must only be plugged into a protection class I 
outlet. The voltage and frequency must exactly be the same as stated on the device. Wrong voltages or 
power outlets can lead to the destruction of the device and to mortal electrical shock. 
 
Always plug in the power plug last. The power plug must always be inserted without force. Make sure that 
the plug is tightly connected with the outlet. 
 
Never let the power-cord come into contact with other cables! Handle the power-cord and all connections 
with the mains with particular caution! Never touch them with wet hands, as this could lead to mortal 
electrical shock. 
 
Never modify, bend, strain mechanically, put pressure on, pull or heat up the power cord. Never operate next 
to sources of heat or cold. Disregard can lead to power cord damages, fire or mortal electrical shock. 
 
The cable insert or the female part in the device must never be strained. There must always be sufficient 
cable to the device. Otherwise, the cable may be damaged which may lead to mortal damage. 
 
Make sure that the power-cord is never crimped or damaged by sharp edges. Check the device and the 
power-cord from time to time. 
 
If extension cords are used, make sure that the core diameter is sufficient for the required power 
consumption of the device. All warnings concerning the power cords are also valid for possible extension 
cords. 
 
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the 
power-cord by the plug. Never pull out the plug by tugging the power-cord. Otherwise, the cable or plug can 
be damaged leading to mortal electrical shock. If the power plug or the power switch is not accessible, the 
device must be disconnected via the mains. 
 
If the power plug or the device is dusty, the device must be taken out of operation, disconnected and then be 
cleaned with a dry cloth. Dust can reduce the insulation which may lead to mortal electrical shock. More 
severe dirt in and at the device should only be removed by a specialist. 
 
There must never enter any liquid into power outlets, extension cords or any holes in the housing of the 
device. If you suppose that also a minimal amount of liquid may have entered the device, it must immediately 
be disconnected. This is also valid, if the device was exposed to high humidity. Also if the device is still 
running, the device must be checked by a specialist if the liquid has reduced any insulation. Reduced 
insulation can cause mortal electrical shock. 
 
There must never be any objects entering into the device. This is especially valid for metal parts. If any metal 
parts like staples or coarse metal chips enter into the device, the device must be taken out of operation and 
disconnected immediately. Malfunction or short-circuits caused by metal parts may cause mortal injuries. 
 

 

 
Keep away children and amateurs! 
 
Never leave this device running unattended. 
 
 

HEALTH HAZARD!

Never look directly into the light source, as sensitive persons may suffer an
epileptic shock (especially meant for epileptics)!

Содержание 42109605

Страница 1: ...Copyright Nachdruck verboten Reproduction prohibited F r weiteren Gebrauch aufbewahren Keep this manual for future needs BEDIENUNGSANLEITUNG USER MANUAL LED KLS 40 COMPACT LIGHT SET...

Страница 2: ...e bersicht 8 INSTALLATION 9 berkopfmontage 9 Montage auf einem Boxenhochst nder 10 Anschluss an den DMX 512 Controller 10 Drahtlose DMX bertragung mit QuickDMX 11 Anschluss ans Netz 11 BEDIENUNG 12 St...

Страница 3: ...uickDMX 29 Connection with the mains 29 OPERATION 30 Stand alone mode 30 Master Slave operation 30 DMX Mode 30 DMX protocol 31 Control Board 38 CLEANING AND MAINTENANCE 39 Replacing the fuse 39 TECHNI...

Страница 4: ...ss Sie lange Zeit Freude an Ihrem Kauf haben werden Nehmen Sie das Produkt aus der Verpackung SICHERHEITSHINWEISE Dieses Ger t hat das Werk in sicherheitstechnisch einwandfreiem Zustand verlassen Um d...

Страница 5: ...zleitung gelten auch f r evtl Verl ngerungsleitungen Ger t bei Nichtbenutzung und vor jeder Reinigung vom Netz trennen Fassen Sie dazu den Netzstecker an der Grifffl che an und ziehen Sie niemals an d...

Страница 6: ...htigkeit oder Nebel zu rechnen ist Feuchtigkeit oder sehr hohe Luftfeuchtigkeit kann die Isolation reduzieren und zu t dlichen Stromschl gen f hren Beim Einsatz von Nebelger ten ist zu beachten dass d...

Страница 7: ...ge mit vier kompakten LED Spots Quertr ger mit integrierter DMX Steuereinheit Absolutes Leichtgewicht bestens geeignet f r mobilen Einsatz Reine Konvektionsk hlung ber K hlrippen keine L fter besonder...

Страница 8: ...Taste 7 Control Board 8 Feststellschraube 9 Schraube 10 LED Linse 11 Spot 12 3 poliger DMX Eingang 13 3 poliger DMX Ausgang 14 QuickDMX Anschluss 15 Spannungsversorgungs eingang 16 Sicherungshalter 17...

Страница 9: ...en Sachkundigen gepr ft werden Vorgehensweise Das Ger t sollte idealerweise au erhalb des Aufenthaltsbereiches von Personen installiert werden WICHTIG BERKOPFMONTAGE ERFORDERT EIN HOHES MA AN ERFAHRUN...

Страница 10: ...swinkel ber den H ngeb gel ein und ziehen Sie die Feststellschrauben gut fest Montage auf einem Boxenhochst nder F r den mobilen Einsatz setzen Sie das Ger t auf einen Boxenhochst nder auf 1 L sen Sie...

Страница 11: ...esen Anschluss l sst sich ein DMX Steuersignal drahtlos auf das Ger t bertragen Der Anschluss ist als 5 polige XLR Einbaubuchse ausgef hrt die die ben tigte Betriebspannung von 5 V f r den Empf nger z...

Страница 12: ...Modus Das Ger t verf gt ber sieben verschiedene DMX Kanal Modi ber das Control Board k nnen Sie wie im Folgenden beschrieben den DMX Kanal Modus definieren Adressierung des Ger ts Um die Startadresse...

Страница 13: ...1D 4 11 S Internes Programm 1 30 49 1E 31 12 19 S Internes Programm 2 50 69 32 45 20 27 S Internes Programm 3 70 89 46 59 27 35 S Internes Programm 4 90 109 5A 6D 35 43 S Internes Programm 5 110 129 6...

Страница 14: ...0 255 F0 FF 94 100 S Rot Gr n Blau Wei 2 Farbvoreinstellungen Spot 2 0 15 00 0F 0 6 S Blackout 16 31 10 1F 6 12 S Rot 32 47 20 2F 13 18 S Gr n 48 63 30 3F 19 25 S Blau 64 79 40 4F 25 31 S Wei 80 95 50...

Страница 15: ...143 80 8F 50 56 S Gr n Blau 144 159 90 9F 56 62 S Gr n Wei 160 175 A0 AF 63 69 S Blau Wei 176 191 B0 BF 69 75 S Rot Gr n Blau 192 207 C0 CF 75 81 S Rot Gr n Wei 208 223 D0 DF 82 87 S Rot Blau Wei 224...

Страница 16: ...0 FF 0 100 F Gr n 0 100 zunehmend 7 Blau Spot 2 0 255 00 FF 0 100 F Blau 0 100 zunehmend 8 Wei Spot 2 0 255 00 FF 0 100 F Wei 0 100 zunehmend 9 Rot Spot 3 0 255 00 FF 0 100 F Rot 0 100 zunehmend 10 Gr...

Страница 17: ...FF 98 100 S Musiksteuerung 2 Dimmerintensit t in Abh ngigkeit von Kanal 1 Werte 0 9 0 255 00 FF 0 100 F Allm hliche Einstellung der Dimmerintensit t von 0 100 3 Strobe in Abh ngigkeit von Kanal 1 Wert...

Страница 18: ...Modus CH Decimal Hexad Percentage S F Eigenschaft 1 Rot Spot 1 0 255 00 FF 0 100 F Rot 0 100 zunehmend 2 Gr n Spot 1 0 255 00 FF 0 100 F Gr n 0 100 zunehmend 3 Blau Spot 1 0 255 00 FF 0 100 F Blau 0 1...

Страница 19: ...0 255 00 FF 0 100 F Allm hliche Einstellung der Dimmerintensit t von 0 bis 100 18 Strobe Spot 3 0 0 00 00 0 0 S Keine Funktion 1 4 01 04 0 2 S Musiksteuerung 5 10 05 0A 2 4 S Keine Funktion 11 255 0B...

Страница 20: ...ntechnische Einrichtungen mindestens alle vier Jahre durch einen Sachverst ndigen im Umfang der Abnahmepr fung gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschin...

Страница 21: ...tes besch digt wird muss sie durch eine besondere Anschluss leitung ersetzt werden die von Ihrem Fachh ndler erh ltlich ist Sollten Sie noch weitere Fragen haben steht Ihnen Ihr Fachh ndler jederzeit...

Страница 22: ...od of time Unpack your product SAFETY INSTRUCTIONS This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely...

Страница 23: ...ion of the device All warnings concerning the power cords are also valid for possible extension cords Always disconnect from the mains when the device is not in use or before cleaning it Only handle t...

Страница 24: ...h water rain moisture or fog may harm the device Moisture or very high humidity can reduce the insulation and lead to mortal electrical shocks When using smoke machines make sure that the device is ne...

Страница 25: ...it Ultra light ideally suited for mobile use Convection cooling entirely via cooling ribs no fans particularly quiet during operation Comes pre assembled 1 four color LED per spot RGB Flicker free pro...

Страница 26: ...on 5 Down button 6 Enter button 7 Control Board 8 Fixation screw 9 Screw 10 LED lens 11 Spot 12 3 pin DMX input 13 3 pin DMX output 14 QuickDMX input 15 Power input 16 Fuse holder 17 Fixation screw 18...

Страница 27: ...cedure trussing systems The device should be installed outside areas where persons may walk by or be seated IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including but not limited to calcul...

Страница 28: ...ation screws Mounting on a speaker systems For mobile use the device may be placed on a speaker system 1 On the speaker system first loosen the fixation screws of the legs Pull out the legs until the...

Страница 29: ...s for wireless transmission of DMX control signals to the device The connector is designed as a 5 pin XLR mounting plug which provides the required 5 V operating voltage for the receiver With QuickDMX...

Страница 30: ...ou as described below to assign the DMX channel mode Addressing Press the MENU button until the display shows DMX Address You can now set the desired address via the UP or DOWN buttons Press ENTER to...

Страница 31: ...ternal program 1 30 49 1E 31 12 19 S Internal program 2 50 69 32 45 20 27 S Internal program 3 70 89 46 59 27 35 S Internal program 4 90 109 5A 6D 35 43 S Internal program 5 110 129 6E 81 43 51 S Inte...

Страница 32: ...lue white 240 255 F0 FF 94 100 S Red green blue white 2 Color presets Spot 2 0 15 00 0F 0 6 S Blackout 16 31 10 1F 6 12 S Red 32 47 20 2F 13 18 S Green 48 63 30 3F 19 25 S Blue 64 79 40 4F 25 31 S Whi...

Страница 33: ...100 S Red green blue white 4 Color presets Spot 4 0 15 00 0F 0 6 S Blackout 16 31 10 1F 6 12 S Red 32 47 20 2F 13 18 S Green 48 63 30 3F 19 25 S Blue 64 79 40 4F 25 31 S White 80 95 50 5F 31 37 S Red...

Страница 34: ...11 255 0B FF 4 100 F Strobe effect with increasing speed 16 Channel Mode CH Decimal Hexad Percentage S F Feature 1 Red Spot 1 0 255 00 FF 0 100 F Red 0 100 increasing 2 Green Spot 1 0 255 00 FF 0 100...

Страница 35: ...S Internal program 4 90 109 5A 6D 35 43 S Internal program 5 110 129 6E 81 43 51 S Internal program 6 130 149 82 95 51 58 S Internal program 7 150 169 96 A9 59 66 S Internal program 8 170 189 AA BD 6...

Страница 36: ...13 Green Spot 3 0 255 00 FF 0 100 F Green 0 100 increasing 14 Blue Spot 3 0 255 00 FF 0 100 F Blue 0 100 increasing 15 WhiteSpot 3 0 255 00 FF 0 100 F White 0 100 increasing 16 Red Spot 4 0 255 00 FF...

Страница 37: ...0 100 F Red 0 100 increasing 8 Green Spot 2 0 255 00 FF 0 100 F Green 0 100 increasing 9 Blue Spot 2 0 255 00 FF 0 100 F Blue 0 100 increasing 10 White Spot 2 0 255 00 FF 0 100 F White 0 100 increasi...

Страница 38: ...ith increasing speed Control Board The Control Board offers several features you can simply set the starting address run the pre programmed program or select a DMX channel mode Browse through the menu...

Страница 39: ...by a skilled installer and any safety problems have to be removed We recommend a frequent cleaning of the device Please use a soft lint free and moistened cloth Never use alcohol or solvents There are...

Страница 40: ...built in microphone LED type COB 30 W Number of LEDs 4 Beam angle 12 Dimensions LxWxH 450 x 120 x 185 mm Weight 3 kg Maximum ambient temperature Ta 45 C Maximum housing temperature TC 60 C Min distan...

Отзывы: