20
6. Maintenance
Your EUROBOOR power tool has been designed to operate over a long period of time with a minimum of
maintenance. Continuous satisfactory operation depends upon proper tool care and regular cleaning.
CAUTION: To reduce the risk of injury, turn unit off and disconnect machine from power source
before installing and removing accessories, before adjusting or changing set- ups or when
making repairs.
Be sure the switch is in the OFF position. An accidental start-up can cause injury.
Just as every magnetic drilling machine with moving parts, your EUROBOOR magnetic drilling machine
also needs regular maintenance service. A few recommendations follow :
Visually check the machine for damage
Machine must be checked before operation for any signs of damage that will affect the operation of the
machine. Particular notice must be taken of the mains cable, if the machine appears to be damaged it
should not be used failure to do so may cause injury or death.
Cleaning
-
Clean all dirt, dust, metal chips and burrs of your magnetic drilling machine
-
Blow dirt and dust out of the main housing with dry air as often as dirt is seen collecting in and
around the air vents. Wear approved eye protection and an approved dust mask
-
Never use solvents or other harsh chemicals for cleaning the non-metallic parts of the tool.
These chemicals may weaken the materials used in these parts. Use a cloth dampened only with
water and mild soap. Never let any liquid get inside the tool; never immerse any part of the tool
into a liquid.
Operation of the machine
The machines operation must be checked to ensure that all components are working correctly. Replace
any defective parts immediately. This prevents properly function parts from being damaged.
Check magnetic base
Before every operation the magnetic base should be checked to make sure that the base is flat and there
is no damage present. An uneven magnet base will cause the magnet to hold not as efficiently and may
cause injury to the operator. When the machine is put out of use for a longer period, apply a small
amount of machine oil to the underside of the magnetic base for rust protection. Clean the magnetic
base again with next use.
Check machine grease
The gearbox grease should be checked once a month to ensure all moving components are covered to
prevent wear. The grease should be changed at least once a year to ensure you gain the best from the
machine.
Carbon brushes
Brushes should be checked to make sure there is no abnormal wear present. This should be checked at
least once a week if used frequently. If the carbon brush has worn more than 2/3 the original length the
brushes should be changed. Failure to do so may cause damage to the machine.