www.euroboor.com
20
5.1 Oil daily
The tool should be lubricated daily (or before each use) with air tool oil (included). During
continuous operation, the tool should be oiled every 1 to 2 hours. For lubricating it is
recommended to use 4 to 5 drops of oil in the air inlet. After which 30 seconds of running is
required to distribute the oil through the tool.
6. Troubleshooting
Problem
Possible Cause
Corrective Action
-
Tool runs slowly or will not
operate
-
No oil in tool.
-
Low air pressure.
-
Air hose leaks.
-
Pressure drops
-
Moisture blowing out of tool
exhaust.
-
Worn rotor blade.
-
Lubricate the tool with EUROBOOR
pneumatic oil IBO.80.
-
Adjust the compressor regulator to 90 PSI
and/or Adjust the regulator on the tool to
maximum setting.
-
Check the air hose for possible leaks and
repair these. Be sure the hose is the proper
size.
-
Do not use a multiple number of hoses
connected together with quick-connect
fittings.
-
Water in tank: drain tank. Oil tool and run
until no water is evident. Oil tool again and
run 1-2 seconds.
-
Abnormal vibration and/or
excessive heat
-
Improper lubrication.
-
Lubricate the tool with EUROBOOR
pneumatic oil IBO.80.
For any problems not in this troubleshooting table, contact your EUROBOOR distributor or