Please read this manual carefully before installation and keep it for future 

reference.

 

 
 
 

INTRODUCTION

 

 

»  Polycrystaline  and  Monocrystaline  Eurener  Photovoltaic  (PEPV/MEPV)  modules  consist  of  crystalline  silicon  solar 
cells,  high  transmission  and  low  iron  toughened  glass,  anti-aging  EVA  and  high  flame  resistant  back  sheet  and 
anodized aluminum alloy frame.

 

»  PEPV/MEPV  modules  are  qualified  for  national  standard  IEC  61215.2  and  IEC  61730,  which  have  passed 
examination of the authorized test center. The manufacturer modules can be used in  roof solar systems,  PV stations, 
communication stations, petrol, ocean,  meteorological, traffic and PV buildings etc.

 

» We are committed to providing technical and installation  support for our customers worldwide.

 

» This Installation Manual is applicable to the installation of  the following PEPV/MEPV modules:

 

 

MEPV***/ MEPV***-B 
PEPV*** / PEPV***-B

 

 

Notes:     1. MEPV*** and PEPV*** is used here as an example.

 

                2. 

“***” is the rated power of the related manufacturer module.

 

 

»  This manual contains important information regarding the  installation, safe handling and maintenance of PV modules 
made by the manufacturer.

 

»  All  instructions  should  be  read  and  understood  prior  to  installing  the  modules. The  installer  should  conform  to  all 
requirements in this manual. The appropriate local  standards and regulations, construction rules and safety

 

instructions should also be  followed during installation. All  work on a PV system must be carried out  by appropriately 
qualified engineers, who must be familiar with the  mechanical and electrical requirements for such a PV  system. 

 
 

DISCLAIMER OF LIABILITY

 

 

» The installation, handling and use of PEPV/MEPV  modules are beyond company control. Therefore, the manufacturer 
assumes  no  responsibility  for  loss,  damage,  injury  or  expense  resulting  from  improper  installation,  handling,  use  or 
maintenance.

 

»  The  manufacturer  reserves  the  right  to  update  the  product,  specifications  or  this  Installation  Manual  without  prior 
notice. 
 
 
 

1) CERTIFICATES REQUESTS 

 

1.1) IEC 61730 

» EURENER modules are designed to fulfill the criteria of Application class A requirements according to IEC 61730-1. 
»  Modules  rated  for  use  in  application  class  A  may  be  used  in  systems  operating  at  greater  than  50V  DC  or  240W, 
where general contact access is anticipated. Modules qualified for safety through IEC 61730-1 and IEC 61730-2 within 
application class A are considered to meet the requirements for safety class 
 
 
 

2) INSTALLATION REQUIREMENTS

 

 

2.1) INSTALLATION ENVIRONMENT  REQUIREMENTS 

 

Avoid shading: 

» Even if the smallest local shelter/shadow (such as dust  deposition) will also decrease the output power. 

 

 

 

Содержание PEPV Series

Страница 1: ...s The installer should conform to all requirements in this manual The appropriate local standards and regulations construction rules and safety instructions should also be followed during installation...

Страница 2: ...ectly at the sun In order to achieve maximum annual yield optimum orientation and tilt of PV modules is necessary The modules which connected in a system must be in same orientation and tilt otherwise...

Страница 3: ...voltage ratings conductor current ratings fuse sizes and size of controls connected to the PV output Only cables with one conductor are to be used recommended to be 4 6 mm length 1000mm temperature r...

Страница 4: ...ded torque is 5Nm Fig 2 Clamping Mounting Types Table 2 Notes 1 indicates 5400pa 550 kg m or 5 4 KN m or 5400 N m is available 2 indicates 2400pa 240 kg m or 2 4 KN m or 2400 N m is available 3 X indi...

Страница 5: ...presents the distance between clamp and frame 2 Dimension P represents the thickness of clamp Type 2 Short Side Mounting Fig 4 Module Type Cell Type Cell Quantity Dimensions mm AxB J K M N P All model...

Страница 6: ...circuit current Isc different from the specifications there may be a wiring fault PEPV MEPV modules use the J Box on the backside of the module it is weatherproof and is designed to be used with stan...

Страница 7: ...s being used However the Voc Voltage of all modules in series should never exceed more than 1000V The plug connector has its own polarity Make sure that the connection is safe and tight Ensure that th...

Страница 8: ...rear of the module using sharp objects Exercise utmost caution when working on wiring and the inverter Be sure carefully to follow manufacture s installation instructions Danger of death from arcing...