Make sure that your Dr.Aquaguard
TM
EDGE is installed by a trained Eureka Forbes Service
Technician only.
1. Input water must be tested for Total Dissolved Solids (TDS).
2. Install your water purifier in a suitably ventilated place. Keep it away from direct sunlight, heating
devices or areas below freezing temperature. You can keep it on the kitchen counter or wall mount it.
3. Ensure that the input water temperature is in the range of 10°C – 40°C. Do not connect to a hot
water tap as it can damage the filters.
4. Make sure that the tap water pressure is not exceeding 3.0 kg/cm
2
for Dr.Aquaguard
TM
EDGE HD
RO+UV+MTDS.
5. After installing, run the purifier for 5-10 mins.
6. Make sure that the reject water pipe (blue coloured pipe available in Dr.Aquaguard
TM
EDGE HD
RO+UV+MTDS model only) is placed lower than the purifier, to avoid stagnation of high TDS reject
water in the pipe.
7.
MTDS Regulator Operating Procedure:
TDS Modulator is located inside the product. As per factory
setting, it comes in completely closed mode. The TDS level of output water can be increased by slowly
loosening (turning anti-clockwise) the spindle of the TDS modulator. Normally, a slight quarter turn is
enough to increase the TDS of output water. Rotating the spindle in clockwise direction closes the TDS
modulator, and reduces the level of TDS blending. Please note that TDS blending and its adjustment is
dependent upon the level of TDS of input water and on the TDS reduction capacity of the RO Membrane.
TDS adjustment should be done by a company authorised personnel only.
INSTALLING YOUR WATER PURIFIER