EunSung Vital Injector 2 Скачать руководство пользователя страница 1

 Operator Manual

 

Содержание Vital Injector 2

Страница 1: ...Operator Manual...

Страница 2: ...ons to improve performance reliability or manufacturability Information furnished by Eunsung Global is believed to be accurate and reliable However Eunsung Global assumes no responsibility for its use...

Страница 3: ...ution 7 2 3 Electrical Hazard 7 3 Medical Safety 3 1 About Medical Safety 8 3 2 Indication for Use 8 3 3 Patient Safety 9 4 Device Description 4 1 Main Console 9 4 2 Injector 10 4 3 Equipment List 11...

Страница 4: ...ti needle mounting exchanging 15 6 7 Mounting Syringe 16 6 8 Connect syringe to multi needle 16 6 9 Tighten syringe holder screw 16 7 Operating Instruction 7 1 About operating instruction 17 7 2 Syste...

Страница 5: ...5 Contents 10 Specification 27 11 Customer Support 27...

Страница 6: ...ing on the clinical use of the system Please contact your local representatives of Eunsung Global whether there are any updated information on available training For information on technical guideline...

Страница 7: ...em is well balanced and is designed to be moved but should always be moved carefully and slowly Verify that the Vital Injector2 is wired for the appropriate electrical voltage of your country 110 VAC...

Страница 8: ...ist in the delivery of stabilized hyaluronic acid filler to restore hydrobalance in the skin and improve skin elasticity and tone to create a revitalized look 3 3 Patient Safety Delivering excessive a...

Страница 9: ...4 Device Description 4 1 Main Console 9 LCD Control Panel Trolley Console Injector Main Body Trolley...

Страница 10: ...tor LCD START STOP Syringe Backward Button Forward Button Connecting Cable 4 Device Description 4 2 Injector The device is conveniently designed easily operated LCD panel on the device enables an oper...

Страница 11: ...cotton ball Manual Multi Needle 20psx box Option Trolley Option 11 4 Device Description 4 3 Equipment List The following equipment is delivered in the shipping pack Call your local dealer if you want...

Страница 12: ...ouched operated by the patients 5 3 Electrical Requirements Please consider the following electrical requirements before installing the system The AC power line power requirements for the system are 1...

Страница 13: ...0 and 105 F 5 to 40 C to optimally store the main console Keep the system in a location where the humidity is between 10 and 80 non condensing Store the system where the air is free of corrosive subst...

Страница 14: ...receptacle 6 Plug the system s power cable into an appropriate electrical outlet 7 Turn the system on 8 Test the system for functional operation of all components and software 6 2 Assemble Main Body T...

Страница 15: ...on 6 5 Mounting filter Mount filter to injector 6 6 Multi needle mounting and exchanging Remove safety guard on multi needle prior to use 15 Remove safety guard immediately after mounting the multi n...

Страница 16: ...ton and insert syringe into needle hole Hold syringe with hand in order to accurately connect syringe in needle hole Slightly push syringe once more to finish up the connection tightly 6 9 Tighten syr...

Страница 17: ...ctor syringes needle and body clean Is the caster fixed Is the power cable connected properly Are the syringe and needle ready 7 2 System Operation 7 2 1 Prepare the system for operation 1 Plug the AC...

Страница 18: ...nstructions 7 2 System Operations 7 2 3 LCD Monitor Control Panel Intermittent mode Preset 10 l 5 6 7 8 9 10 11 12 13 14 15 20 25 30 l Continuous mode Preset 1 cc min 1 cc 1 2 3 cc min 2 3 5 cc 1 3 5...

Страница 19: ...5Pin Total 5 Mute Press the icon once to mute the sound of the buttons Press again to set back to normal 6 Treatment Mode Two types of treatment mode is programed Press the tab to change between INTER...

Страница 20: ...the standard in case of others at least two times of alarm signals would be heard 3 Upon hearing the alarm signal the operator needs to immediately stop the treatment and check the residual amount of...

Страница 21: ...een to select then adjust the depth by using upward downward arrowson the right Range 0 0mm 5 0mm Interval 0 2mm 3 Syringe Volume cc Type Select desired volume of syringe for operator s medical needs...

Страница 22: ...3 Standby Ready Standby Ready Keep pressing the button for 2 seconds then it automatically moves back to the place where the position holder and syringe holder match Auto reference positioning functi...

Страница 23: ...r Turn off the device and clean the outer plastic casing with dry towel Prevent the needle connector from sticking dirty substances 8 2 4 Console The outer surface of the system may be wiped clean wit...

Страница 24: ...press the STADNBY READY button at the injector for more than 2 seconds Then user would decide whether to go back to factory setting or not Forward button at the right Proceed on to factory setting Bac...

Страница 25: ...it for 10 seconds then turn on the device The monitor s power problem Check the connection status of the injector connector Operating Problem System error message Verify progress in the correct syring...

Страница 26: ...ckless willful or intentional conduct Damages caused by a product or part that has been disconnected modified arbitrary repaired altered without the permission or supervision of trained personnel from...

Страница 27: ...bal co kr Manufacturer Needle Information 31 G 5Pin Multi Needle Type Needle Penetration Control 0 0 5 0 mm Interval 0 2mm Syringe Type 1cc 2cc 3cc 5cc Operation Mode Intermittent Continuous Voltage F...

Страница 28: ...History Ver Date Revision Details Author V1 2015 04 Eng ver of Vital Injector2 s operator manual is completed Kim SW 28...

Страница 29: ......

Отзывы: