Operating Instructions
Modular Safety Control System MSC
118
(Translation of the original operating instructions) 2121331-04-04/19
9.3.1. Speed monitoring (SPEED CONTROL)
The speed monitoring function block checks the speed of a device. The OVER output is "0" (FALSE) if the speed measured
exceeds a limit set previously. If the speed is below this previously set limit, the OVER output is "1" (TRUE).
Figure 125: Speed monitoring
Parameter
Axis type: Defines the type of axis that is monitored by the device. "Linear" if the movement is linear or "Rotational" if the
movement is rotary.
Sensor Type: If "Linear" is selected for the previous parameter, the sensor type connected to the inputs of the module is
defined here. "Rotational" (e.g. encoder on a toothed rack) or "Linear" (e.g. optical linear sensor). This selection defines the
other parameters.
Measuring device: Defines the type of measuring device/sensors used. The following can be selected:
Ì
Encoder
Ì
Proximity
Ì
E proximity
Ì
Proximity 1 + Proximity 2
Ì
Encoder 1 + Encoder 2