9. Initialization
To enable the communication interface, the hand-held pendant station must be initialized.
The initialization is performed either by polling the current states of the keys with the
"Status polling" ("Statusabfrage") function (section 9.1) and the transfer of parameters
(section 9.2), or by sending another valid command byte (section 10.3 Overview of
commands).
The baud rate is also set on initialization (see section 5).
9.1 Status polling (command byte 23H)
The state of the keys and the error byte can be polled by the control system at any time
using the command byte 23H.
The error byte remains set until a status poll has been performed or a further error-free
transfer is made.
After the status polling the error byte is reset to 31H (no error).
It is recommended to perform a status poll for initialization after the reception of a NAK
character, as in this way the HBAS is reset.
The control system requests the current status from the HBAS
HBAS
Control system
Byte 1
STX
(02H)
Byte 1
DLE
Byte 2
STATUS WORD
(23H)
Byte 3
DLE
(10H)
Byte 4
ETX
(03H)
Byte 5
BCC
Byte 2
DLE
The HBAS sends its current status to the control system
Control system
HBAS
Byte 1
STX
(02H)
Byte 1
DLE
Byte 2
KEY BYTE
(see section 7)
Byte 3
ERROR BYTE
(see section 9)
Byte 4
DLE
(10H)
Byte 5
ETX
(03H)
Byte 6
BCC
Byte 2
DLE
The control system is only allowed to continue the transfer of data when the HBAS has
completed the transfer of the status.
Содержание HBAS 094594
Страница 1: ...Handbedienger t mit Display HBAS 094594 Handbuch...
Страница 39: ...EUCHNER Handbedienger t HBAS 094594 095640 02 02 06 Technische nderungen vorbehalten Seite 39 40...
Страница 41: ...Hand Held Pendant Station with Display HBAS 094594 Manual...
Страница 79: ...EUCHNER Hand Held Pendant Station HBAS 094594 095640 02 02 06 Subject to technical modifications Page 39 40...