![EUCHNER CET.-AR Series Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/euchner/cet-ar-series/cet-ar-series_operating-instructions-manual_2434843024.webp)
Operating Instructions
Transponder-Coded Safety Switch CET.-AR-…
24
(Translation of the original operating instructions) 2110788-13-03/20
10.6.3. Version with door monitoring output (CET3/4) and additional monitoring output OUT on X 2.3
Wiring diagram C
Plug connector
(view of connection side)
Pin
Designation
Function
Conductor coloring
of connecting ca-
ble
1)
2 x M12
X2.5
X1.8
X1.5
X1.6
X1.7
X1.2
X2.4
X2.3
X2.1
X2.2
X1.4
X1.3
X1.1
X 1.1
IB
Enable input for channel B
WH
X 1.2
U
B
Operating voltage of AR electronics, 24 V DC
BN
X 1.3
OA
Safety output channel A
GN
X 1.4
OB
Safety output channel B
YE
X 1.5
OUT
Monitoring output
GY
X 1.6
IA
Enable input for channel A
PK
X 1.7
0 V U
B
Operating voltage of AR electronics, 0 V
BU
X 1.8
RST
Reset input
RD
X 2.1
0 V U
CM
Operating voltage of guard locking solenoid, 0 V
BN
X 2.2
OUT D
Door monitoring output (indication on LED 2)
WH
X 2.3
OUT
Monitoring output
BU
X 2.4
U
CM
Operating voltage of guard locking solenoid, 24 V DC (indication on
LED 1)
BK
X 2.5
-
n.c.
GY
1) Only for standard EUCHNER connecting cable.
10.7. Connector assignment for safety switch CET-AR with plug connector M23 (RC18)
10.7.1. Version without door monitoring output (CET1/2)
Wiring diagram D
Plug connector
(view of connection side)
Pin
Designation
Function
Conductor coloring
of connecting
cable
1)
M23 (RC18)
With shield
spring
18
19
15
12
11
9
5
4
3
2
1
17
16
14
13
6
10
8
7
1
U
CM
Operating voltage of guard locking solenoid, 24 V DC
VT
2
IA
Enable input for channel A
RD
3
IB
Enable input for channel B
GY
4
OA
Safety output channel A
RD/BU
5
OB
Safety output channel B
GN
6
U
B
Operating voltage of AR electronics, 24 V DC
BU
7
RST
Reset input
GY/PK
8
-
n.c.
GN/WH
9
-
n.c.
YE/WH
10
OUT
Monitoring output
GY/WH
11
-
n.c.
BK
12
FE
Function earth:
This connection must be connected to 0 V.
GN/YE
13
J
Version with teach-in input:
To teach-in a new actuator, connect to 24 V DC; leave open in normal
operation.
2)
PK
Y
Version with feedback loop:
If the feedback loop is not used, connect to 24 V DC.
-
Version without feedback loop and without teach-in input:
This connection must be connected to 0 V.
14
-
n.c.
BN/GY
15
LED 1
LED 1 red, freely configurable, 24 V DC
BN/YE
16
LED 2
LED 2 green, freely configurable, 24 V DC
BN/GN
17
-
n.c.
WH
18
0 V U
CM
Operating voltage of guard locking solenoid, 0 V
YE
19
0 V U
B
Operating voltage of AR electronics, 0 V
BN
1) Only for standard EUCHNER connecting cable.
2) With dual-channel solenoid control, do not connect to 0 V U
B