13
2110788-13-03/20 (Translation of the original operating instructions)
Operating Instructions
Transponder-Coded Safety Switch CET.-AR-…
EN
7.2. Emergency release (can be retrofitted)
Permits opening of a locked guard from outside the danger zone without tools. For mounting, see the mounting supplement.
The safety outputs are switched off when the emergency release is actuated. Use the safety outputs
to generate a stop command
.
The monitoring output OUT is switched off; OUT D can assume an undefined state. Open the guard and close it again after
resetting the emergency release. The device will then operate normally again.
Important!
Ì
It must be possible to operate the emergency release manually from outside the protected area
without tools.
Ì
The emergency release must possess a marking indicating that it may be used only in an emergen-
cy.
Ì
The actuator must not be under tensile stress during manual release.
Ì
The emergency release must be sealed or the misuse of the release function must be prevented in
the control system.
Ì
The release function meets all other requirements from EN ISO 14119.
Ì
The emergency release meets the requirements of Category B according to
EN ISO 13849-1:2015.
Ì
Loss of the release function due to mounting errors or damage during mounting.
Ì
Check the release function every time after mounting.
Ì
Please observe the notes on any enclosed data sheets.
7.2.1. Actuating emergency release
Turn emergency release clockwise until it clicks into place.
¨
Guard locking is released.
To reset, press the snap-in bolt inward using a small screwdriver or similar tool and turn
the emergency release back.
25
30,4
L
Snap-in bolt