Operating Instructions
Non-Contact Safety Switch CES-I-AS2A-M-C04
12
(translation of the original operating instructions) 2120545-05-08/18
10. System status table
Operating mode
Actuator/door po
-
sition
CES LED indicator
Output
State
ST
ATE (gr
een)
DIA (r
ed)
Normal operation
closed
Normal operation, door closed
closed
flashing
quickly
Normal operation, door closed, actuator in limit range
¨
Re-adjust door
open
1 x
Normal operation, door open
Fault display
closed
3 x
Defective actuator (e.g. fault in code or code not readable)
X
Internal fault (e.g. component faulty, data error)
Key to symbols
LED not illuminated
LED illuminated
10 Hz (8 s)
LED flashes for 8 seconds at 10 Hz
3 x
LED flashes three times, and this is then repeated
X
Any state
After the cause has been remedied, faults can generally be reset by opening and closing the safety guard. If the fault is
still displayed afterward, briefly interrupt the power supply. Please contact the manufacturer if the fault could not be reset
after restarting.
Important!
If you do not find the displayed device status in the system status table, this indicates an internal device
fault. In this case, you should contact the manufacturer.