Operating instructions
Non-Contact Safety System CES-AZ-UES-…
20
(Translation of the original operating instructions) 2105274-12-08/20
11. Technical data
11.1. Evaluation unit CES-AZ-UES-01B
Ì
Housing for rail mounting, IP20
Ì
Relay output
Ì
1 read head can be connected
Dimension drawing
114
22,5
99
Safety Unit
CES-AZ
H11
+UB
H12
0V
SH1
STATE OUT DIA
13 O1 Y1 23
14 DIA Y2 24
Multicode
RESET
TST
J
S
S
Y
56
Suitable for standard 35 mm mounting rail
Switching characteristics
Ì
2 safety outputs with 2 NO contacts each
(relay outputs)
Ì
1 door monitoring output (semiconductor
output, not a safety output)
Important!
The plug-in screw terminals are not included (see chapter
12. Ordering information and accessories
).
Approvals
Guard
closed
(actuator detected)
open
(actuator not in the actuating range)
Read head
Actuator
Read head
V
O1
13
14
23
24
24
13
14
23
24
24 V
O1