Operating Instructions
Transponder-Coded Safety Switch CTM-C2-BP/BR-FLX
18
(translation of the original operating instructions) MAN20001574-01-09/22
10. Connection of a single CTM-BP/BR (separate operation)
WARNING
In the event of a fault, loss of the safety function due to incorrect connection.
Ì
To ensure safety, both safety outputs FO1A and FO1B must always be evaluated.
Important!
The example shows only an excerpt that is relevant for connection of the CTM system. The example
illustrated here does not show complete system planning. The user is responsible for safe integration
into the overall system. Detailed application examples can be found at www.euchner.com. Simply enter
the order number of your switch in the search box. You will find all available connection examples for
the device in
Downloads
.
Connected load
BR evaluation
via PLC
Safety Outputs
Read Head
CTM
Door
Monitoring
Monitoring Outputs
Diagnostic
Locking
active
FO1A
3
FO1B
4
OD/C
6
OL
7
-B1
UB
2
IMP
1
0VUB
8
OI
5
13
14
-S1
1
2
-F1
1
2
-F2
24V DC
0 V
24V DC
0 V
Actuator config L
Actuator
EUC.170487
Fig. 1:
Connection example, separate operation