6 Electrical connection
Danger!
Electrical connection may be performed only by
authorized personnel trained in EMC
and with the
device and wiring
isolated
.
Warning!
For use and operation as per the
requirements, a power supply with the feature
“for use in
class 2 circuits”
must be used.
Attention!
The read/write station is allowed to be connected only if it is electrically isolated.
Otherwise the device can be damaged.
Attention!
If connected incorrectly, the device can be damaged.
Observe electrical characteristics and terminal assignment (see chapter 4.4 Technical data for compact
version and chapter 4.5 Technical data for modular version).
Attention!
All the electrical connections must either be isolated from the mains supply by a safety transformer
according to IEC/EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent
isolation measures.
Attention!
When connecting, the operating organization must ensure compliance with the EMC protection
requirements in accordance with EN 55011 and EN 61000-6-2.
Attention!
The equipotential bonding system of the machine installation must comply with EN 60204-1, section 8,
Equipotential bonding.
Attention!
Do not lay connecting cables in the immediate vicinity of sources of interference.