Operating Instructions
Non-Contact Safety Switch CES-A-C5H-EX
28
(Translation of the original operating instructions) 2110182-10-02/20
13.3.2. Typical actuating range
Only in combination with actuator CES-A-BBA-EX.
X
25
15
20
10
5
20
25
30
5
10
15
-30
30
-30
25
20
15
10
5
Y
Z
For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the
actuating range of the side lobes is not entered.
13.3.3. Actuating range for center offset m = 0
1)
Parameter
Value
Unit
min.
typ.
max.
Assured operating distance S
ao
18
-
-
mm
Operating distance
-
20
-
Switching hysteresis
2
3
-
Assured release distance S
ar
-
-
40