background image

®

www.etsnord.com

5

®

RDM-38-1120

4.2  Installation of the ceiling panel between the modules

5.  Installing the steam filters

D

 C 

E

A

B

C

D

D

E

M5/10

ø4/16

E

Содержание NORDcanopy HU

Страница 1: ...NORDcanopy HU Installation use and maintenance manual www nordcooking com ...

Страница 2: ...kitchen canopy modules together 4 5 Installing the steam filters 5 6 Connecting the condensation drain 6 7 Lighting connection 6 8 Measuring and adjusting airflow 7 9 Accessories 8 10 Kitchen canopy maintenance 8 1 Supply air adjustment plate 2 Supply air connection 3 Exhaust air connection 4 Exhaust air adjustment plate 5 Suspension points 6 Lighting 7 Front panel 8 Front panel lock 9 Airflow mea...

Страница 3: ...0 L1 25 L1 30 L2 25 40 48 15 48 D E F C 1 2 3 4 B A 3 2 1 5 6 7 8 ETS NORD AS LEHT 1 1 M Tähis Nimetus Materjal Kinnitas Kontrollis Teostas 25 08 2020 Hannes Lung HU juhendi joonis MASS A Safety It is prohibited to hold or add additional weight on the top of the canopy A B D D E M5 10 E ...

Страница 4: ...ormed for each module 3 Opening the front panel The panel locks automatically ATTN At the end of the installation make sure that the panels are correctly fixed 5x B 4x B 4 Fastening kitchen canopy modules together 4 1 Sequential connection A B C D D E M5 10 ø4 16 E ...

Страница 5: ... www etsnord com 5 RDM 38 1120 4 2 Installation of the ceiling panel between the modules 5 Installing the steam filters D C E A B C D D E M5 10 ø4 16 E ...

Страница 6: ... www etsnord com 6 RDM 38 1120 6 Connecting the condensation drain 7 Lighting connection ATTN Performed by electrician 3 8 3 8 a b L N PE ...

Страница 7: ...0 43 8 37 6 30 9 27 0 2000 77 9 68 7 58 1 51 5 2500 83 8 72 7 60 5 53 1 3000 87 7 75 2 61 9 54 0 3500 123 2 107 4 89 7 79 0 4000 155 7 137 5 116 2 102 9 4500 162 3 142 0 118 9 104 8 5000 167 6 145 4 120 9 106 2 5500 171 9 148 2 122 5 107 2 6000 175 3 150 4 123 8 108 0 Adjusting plate located behind HFU condensation plates is used for adjusting exhaust airflow For fixing the regulating plate lock t...

Страница 8: ...the surfaces after cleaning in order to avoid harmful interactions of cleaning agents and high temperatures To clean the exhaust chamber HFU condensation plates are removed from the kitchen canopy To clean the supply chamber the front panel of the kitchen canopy is removed ATTN Do not use hard or abrasive detergents chlorine or bleach when cleaning the canopy Never clean the kitchen canopy when an...

Страница 9: ...land Address Pakkasraitti 4 04360 Tuusula Finland Phone 358 0401 842 842 info etsnord fi www etsnord fi ETS NORD Denmark Address Nordholmen 6 2650 Hvidovre Denmark Phone 45 9712 1314 info etsnord dk www etsnord dk ETS NORD Sweden Address Järsjögatan 7 69235 Kumla Sweden Phone 46 707 80 50 16 info etsnord se www etsnord se ...

Отзывы: