ets-lindgren.com
EMSwitch Command Set
35
Description / Command
Reply
Set switch 2 of EMSwitch Remote Relay 1 to
position 3.
N11RELAY_2_3
OK
Set switch 2 of EMSwitch Remote Relay 2 to
position 4.
N12RELAY_2_4
OK
Get position of switch 2 of EMSwitch Remote
Relay 1.
N11RELAY_2?
One of the following:
!, 2, 3, 4, 5, 6
Get position of switch 3 of EMSwitch Remote
Relay 2.
N12RELAY_3?
One of the following:
!, 2, 3, 4, 5, 6
Set switch type of switch 3 of EMSwitch Remote
Relay 2 to 1 to 2, 1 to 3, 1 to 4, 1 to 5, or 1 to 6.
N12RELAYTYPE_3_2
N12RELAYTYPE_3_3
N12RELAYTYPE_3_4
N12RELAYTYPE_3_5
N12RELAYTYPE_3_6
OK
Get switch type of switch 3 of EMSwitch Remote
Relay 2.
N12RELAYTYPE_2?
One of the following:
2, 3, 4, 5, 6
Disable readback to switch 3 of EMSwitch Remote
Relay 2.
N12READBACK_3_0
OK
Enable readback to switch 3 of EMSwitch Remote
Relay 2.
N12READBACK_3_1
OK
Get readback status to switch 3 of EMSwitch
Remote Relay 2.
N12READBACK_3?
0 (disabled)
OR
1 (enabled)
Содержание 7001-001
Страница 6: ...vi ets lindgren com This page intentionally left blank ...
Страница 16: ...16 Specifications ets lindgren com This page intentionally left blank ...
Страница 24: ...24 EMSwitch Remote Relay ets lindgren com This page intentionally left blank ...
Страница 38: ...38 EMSwitch Command Set ets lindgren com This page intentionally left blank ...
Страница 42: ...42 Typical Data ets lindgren com ...
Страница 43: ...ets lindgren com Typical Data 43 VSWR The average power input must be reduced for load VSWR above 1 1 ...
Страница 44: ...44 Typical Data ets lindgren com This page intentionally left blank ...