22
PREP
ARING FOR OPERA
TION
Left Bar, Right Bar Smart Cylinder (Variable Width Bar Only)
Tap the Left Bar/Right Bar Smart Cylinder Calibration buttons to go to their calibration screen. Refer to Figures 18 & 19.
To begin, press the green START button, and fully extend the spray bar. The feedback value, given in millivolts
[mV], will increase as the spray bar extends. Once the spray bar is fully extended, feedback will read close to
4500 mV. Next, fully retract the spray bar. The feedback value will decrease as it retracts. Once the spray bar is
fully retracted, feedback will read close to 500 mV. Press the STOP button once fully retracted and the calibration
will save. The extend and retract parameters will flash, to indicate new calibrations have been saved into mem
-
ory. The red reset button will default calibrations to their factory values of 4700 mV for extend and
300 mV for retract.
Setup
Figure 18 - Machine Calibrations Window
Figure 19 - Left Bar Smart Cylinder START Calibrate Window
WARNING
Distributors with a variable-width spray bar
must calibrate the smart cylinder on each
the left spray bar and right spray bar. These
screens allow the operator to calibrate the
smart cylinder feedback. This should not be
performed in the field unless wiring to the
smart cylinder has been replaced.