background image

Water Booster Sets                                                                                                 

Assembly, Operation, Service, Maintenance Manual

Содержание ETNA 1 SCT 100-50

Страница 1: ...Water Booster Sets Assembly Operation Service Maintenance Manual...

Страница 2: ...ules 03 2 Handling and Transportation 04 3 Human and Environment Health 04 4 Usage Errors 04 5 Product Specifications 04 5 1 Booster Parts 04 5 2 Technical Specifications and Outside Dimensions 05 6 U...

Страница 3: ...ance repair or modification performed by a party other than our authorized service providers or from any tempering or recalibration attempt besides the maintenance repair cleaning defined in Article 7...

Страница 4: ...rrors Please read and follow this manual carefully to avoid usage errors Any action against the instructions of this manual will be named as an usage error and will not be covered by the warranty 5 Pr...

Страница 5: ...00 24 220 V 1 1 1 1 8 0 6 30 43 5 6 24 L 300 470 630 490 20 ETNA JET INOX 100 50 220 V 1 1 1 1 8 0 6 30 43 5 6 50 L 350 500 685 545 25 ETNA YPH 60 50 220 V 1 5 1 1 4 1 3 6 47 10 15 50 L 350 500 675 54...

Страница 6: ...re is still dropping it means the non return valve is not working Replace it The air in the expansion tank is discharged Call the service No water is being pumped even though the booster is working an...

Страница 7: ...nsure that your product is mounted by authorized technicians in line with the installation layout given on the user manual Call a technical service for starting up the product 8 1 Location Selection T...

Страница 8: ...tive Water Reserve Layout 1 3 5 5 1 Float Switch Float Switch Max Level NOT Booster suction pipe diameter should be smaller than the pump suction nozzle diameter If the booster sticks water from below...

Страница 9: ...5 6 4 5 7 8 2 From the mains To the building 3 0 1 2 3 4 5 6 7 8 5 5 1 Power Failure On Reset ETNA 1 Hydromat automatic 2 Pump 3 Silt Trap 4 Check Valve 5 Slide Valve 6 Service Pipe 7 Float Valve 8 Wa...

Страница 10: ...fail or to be below the capacity If possible the suction pipe should be tested with pressurized water The pipe of the suction line should be as smooth and as short as possible and use of excessive jo...

Страница 11: ...er from a water tank open the suction line valves and release the air by the air discharge plug Wait until the water reaches the pump Close the air discharge plug when water reaches to the pump If the...

Страница 12: ...Dudullu Organize Sanayi B lgesi 2 Cadde No 14 34775 mraniye Istanbul Turkey Tel 90 216 561 47 74 Pbx Fax 90 216 561 47 50 www etna com tr en info etna com tr customer service...

Отзывы: