background image

Superior Pro-Heat Programmable Thermostat User’s Manual 
 
Model: 031530 
 

The Pro-Heat thermostat is suitable for floor heating systems, 
controlling the voltage of either a 120VAC or 240VAC. 

I.

 

Main Functions and Features 

 

Blue backlight, clear display 

 

Independent keys, easy to operate 

 

Can be controlled via sensors or time 

 

Factory set with 4 programmed schedules for user’s 
choice 

 

Remote on/off control to connect to a home automation 
system 

 

Calculates the heating time which helps calculate the 
energy consumption 

 

Keyboard lock function 

 

II.

 

Product Details & LCD Display 

 

III.

 

Installation and Wiring 

 

Installation 

  Installation must be carried out by a certified electrician 

and must comply with national and local electrical 
codes. 

o

 

Open the keypad cover and 
loosen the screw allowing for the 
separation of the front module 
from the power module.

 

o

 

Pull outward near the bottom of 
the front module and lift off.

 

o

 

Find a location for the 
thermostat in your home.  It is 
for indoor use only.  Install the 
thermostat at a height between 
4 and 5 feet above the floor, or 
on an inside wall.  Direct 
sunshine and heat appliances 
should be avoided.

 

o

 

Turn off the power to the floor 
warming system before doing 
any electrical work.

 

o

 

A dedicated circuit is ideal for the installation of this 
thermostat.  If a dedicated circuit is not possible, make 
sure there is enough load capacity on an existing circuit 
to handle the addition of your floor warming system.  
This circuit should NOT be wired in series with any 
other device including other GFCIs.

 

o

 

The circuit breaker in the main circuit panel should be 
15 amps maximum for a floor warming system totaling 
12 amps or less.  For a larger system up to 15 amps, use 
a 20 amps maximum circuit breaker.  NEVER exceed 15 
amps on the thermostat.

 

o

 

Pull the power supply wiring in to this box, leaving 
about 6 inches of wire.

 

o

 

Refer to your floor warming system.  Pull the floor 
sensor wire and the power lead wires from your floor 
warming system up the wall 
in to this box.

 

o

 

Mount the electrical panel.

 

CAUTION:  

High Voltage—

Disconnect power supply 
before servicing.

 

Do NOT use where exposed 
to rain.

 

Mount this control only to a 
grounded metallic box or a 
nonmetallic box.

 

 

Wiring 

Line1 (

L

) and Line2 (

N

) (Line 

120VAC/240VAC) and Load1 
(

LOUT

) and Load2 (

NOUT

)

 

o

 

Connect 

L

 and 

N

 to the power supply with the wire 

nuts.  Gently tug on the wires to make sure there is no 
failure in the connection.  Consider wrapping the wire 
nuts with electrical tape to secure the wire connection 
tightly.

 

o

 

Connect 

LOUT

 and 

NOUT

 to the floor warming system 

lead wires with the wire nuts.  Gently tug on the wires 
to make sure there is no failure in the connection.   
Consider wrapping the wire nuts with electrical tape to 
secure the wire connection tightly.

 

o

 

Connect the house ground wire to the green lead wire 
of your floor warming system.

 

o

 

Insert the ends of the floor sensor in to the terminal 1 
and 2 and tighten the screws.  The blue wire should be 
secured in terminal 1 and the red wire should be 
secured in terminal 2. 
Note: Before continuing, make sure your power supply 
voltage matches the voltage rating of your floor 
warming system.  Connecting 240VAC to a 120VAC 
floor warming system will cause overheating and 
damage to the system and may damage the controller, 
other wiring, floor coverings, etc. 

IV.

 

Parameter Setup 

 

On/Off Switch 

Found on the side of the thermostat.  The switch must be 
placed in the “

on

” position to allow any of the 

programming to function.  When in the “

off

” position, the 

system will not heat and the keys will not function. 

 

Setting the Date and Time 

o

 

Press and hold the 

Day/Time

 button 

until the 

hour

 begins to flash.  Press 

 

or 

 to adjust the hour. 

o

 

Press the 

Day/Time

 button again and 

the 

minutes

 will begin to flash.  Press 

 

or 

 to adjust the minutes. 

o

 

Press the 

Day/Time

 button again and the 

day of the 

week

 along the top will flash.  Press 

 or 

 to adjust 

the day of the week.   

o

 

Press the 

Hold/Return

 button once more and your 

settings will be stored. 

 

Switching Between °F/12 h and °C/24h Format 

o

 

Press and hold the 

Options

 

button.  

°F and 12 h

 will show 

on the display. 

o

 

Press 

 or 

 to toggle 

between 

°F and 12 h

 and 

°C 

and 24h

o

 

Press the 

Hold/Return

 button to store your settings. 

 

 Setting Your Heating Schedule 

There are four factory set 
schedules you can use, 
designated P1, P2, P3, and P4.  

Отзывы: