Страница 1: ...DOC_DEV_XSLAN _User guide_B XSLAN SHDSL Switch _________________ USER GUIDE _________________ ...

Страница 2: ...EV_XSLAN _User guide_B The XSLAN SHDSL switch is designed and manufactured by ETIC TELECOM 13 Chemin du vieux chêne 38240 MEYLAN FRANCE TEL 33 0 4 76 04 20 05 E mail hotline etictelecom com web www etictelecom com ...

Страница 3: ...rge EN61000 4 3 RF Radiated Immunity EN61000 4 4 EFT Burst Immunity EN61000 4 5 Surge Immunity EN61000 4 6 RF Conducted Immunity EN61000 4 8 Power Frequency Magnetic Field Immunity EN 61000 6 4 2007 A1 2011 Emission EN55022 Radiated and conducted emission EN 60950 1 A2 2014 Safety and Health Date 11th October 2017 Philippe Duchesne Technical Director NOTE This equipment has been tested and found t...

Страница 4: ......

Страница 5: ...ety instructions 24 3 DIN rail mounting 25 4 Cooling 25 5 Power supply 25 6 Isolation and earthing 26 7 RS232 serial connection XSLAN X220 or XSLAN X230 26 8 RS485 serial connection XSLAN X220 26 9 RS422 isolated serial connection XSLAN X260 27 10 RS485 isolated serial connection XSLAN X261 28 11 Digital input and output 29 12 Preparing and checking the line 29 12 1 Type of cable 29 12 2 Crosstalk...

Страница 6: ... 2 First configuration 34 1 3 Changing the configuration later 34 2 Temporary return to the factory settings 35 3 Restoring the factory settings 35 4 Protecting the access to the administration server 36 5 Configuration steps 36 ANNEX 1 SHDSL data rate versus distance 37 ...

Страница 7: ...N 1400 XSLAN 1220 XSLAN 1230 XSLAN 1260 XSLAN 1261 XSLAN 2400 XSLAN 2220 XSLAN 2230 XSLAN 2260 XSLAN 2261 XSLAN BP2400 XSLAN BP2220 XSLAN BP2230 XSLAN BP2260 XSLAN BP2261 XSLAN 4200 XSLAN BP4200 The main features are summarized hereafter XSLAN models 1400 12xx 2400 22xx BP2400 BP22xx 4200 BP4200 SHDSL port 1 1 2 2 2 2 4 4 Max data rate Mb s 15 2 15 2 30 4 30 4 30 4 30 4 60 8 60 8 Ethernet port 10 ...

Страница 8: ... 4KV line earth RF conducted EN61000 4 6 Magnetic fields EN61000 4 8 Emission conducted and radiated EN 55022 Electrical safety EN 60950 1 Hazardous materials 2011 65 UE RoHS REACH SHDSL ITU T G 991 2 802 3ah 2BaseTL EFM Data rate 192 kb s to 15 2 Mb s on 1 pair Isolation 1500 V Connection time 45 s typical STU C STU R auto negotiation Latency Frame transmission delay from one Ethernet port of an ...

Страница 9: ...HDSL LINE MIB HOST RESOURCES MIB IF MIB IP MIB BRIDGE MIB RSTP MIB RS232 RS485 Asynchronous 1200 à 115200 kb s with or without parity Gateway Raw TCP client and server UDP multipoint Multicast Telnet Modbus Unitelway Date and time NTP client and server Log Log with timestamp of the last 300 events Syslog Alarm 1 digital output SNMP traps Configuration With HTML browser depending on models ...

Страница 10: ...ey provide a serial port They are named XSLAN 2XXX hereafter The products which can be connected to four twisted pair They provide four SHDSL interfaces The references of that products are XSLAN 4200 4 1 XSLAN 1XXX Point to point link on a single twisted pair Two XSLAN 1XXX extend Ethernet over one twisted pair The data rate is up to 5 7 Mb s on 3 7 Km and 15 Mb s on 0 7 Km see table in Annex 1 4 ...

Страница 11: ...the other pair backup Daisy chain link The XSLAN 2XXX is used to interconnect a series of Ethernet networks using a single twisted pair Thanks to the Store and Forward principle the number of switches is not limited Point to multipoint link The XSLAN 2XXX is used to interconnect a central site with two remote sites ...

Страница 12: ...protocol 4 3 XSLAN 4200 Additional features compared to XSLAN 2XXX Point to point link on four twisted pairs Two XSLAN 4200 extend Ethernet over two three or four aggregated twisted pair The data rate is the sum of the data rate on each pair up to 22 8 Mb s on 3 7 Km and 60 Mb s on 0 7 Km see table in Annex 1 In case of a failure of one or more pairs the data transmission is maintained on the rema...

Страница 13: ... XSLAN 4200 is used to interconnect a central site with four remote sites Point to multipoint link with doubled data rate The XSLAN 4200 is used to interconnect a central site with two remote sites Redundant ring with doubled data rate Redundant ring with 2 pairs aggregated on each side ...

Страница 14: ... two will switch to STU R 5 2 Redundancy solutions RSTP and proprietary failsafe ring Industrial applications need reliable networks one way to provide reliability is to provide backup paths which form loops in the Ethernet network However loops are highly unwelcome in Ethernet networks as they can cause broadcast storms eating up all the available bandwidth and causing network outage The goal of ...

Страница 15: ...l function called the By pass function The XSLAN BP includes an electro mechanical relay between both lines that relay is automatically closed to connect the two lines when the XSLAN BP is switched off For instance if the XSLAN 2 cabinet is switched off for maintenance the by pass relay inside the XSLAN 2 will automatically connect the line coming from the XSLAN 1 to the line going to the XSLAN 3 ...

Страница 16: ...RJ45 Ethernet interfaces or 2 Ethernet and 1 or 2 serial interfaces associated with a gateway function that allows the easy integration of equipment with RS232 or RS485 or RS422 serial interface to the Ethernet network IP routing and filtering The XSLAN can remove the broadcast frames on the SHDSL link by routing the IP frames and thus limiting the unwanted traffic on the SHDSL link VLAN The XSLAN...

Страница 17: ...User guide_B Page 17 INSTALLATION 1 Description 1 1 Dimensions All models XSLAN 1XXX or XSLAN 2XXX or XSLAN 4200 The height indicated ignores the bulk of the power connector on the bottom side 1 2 Connectors XSLAN 1400 XSLAN 1220 ...

Страница 18: ...INSTALLATION Page 18 DOC_DEV_XSLAN _User guide_B XSLAN 1230 XSLAN 1260 XSLAN 1261 XSLAN 2400 For XSLAN 22XX See XSLAN 12XX ...

Страница 19: ...INSTALLATION DOC_DEV_XSLAN _User guide_B Page 19 XSLAN BP2400 For XSLAN BP22XX See XSLAN 12XX XSLAN 4200 XSLAN BP4200 The By passed ports are port 3 and port 4 only ...

Страница 20: ...ition Signal Function 1 3V3 3 V DC provided by the XS 2 In Digital input 3 F Digital output max 48Vdc 0 5A 4 F Digital output XSLAN 1XXX or XSLAN 2XXX or XSLAN 4200 2 positions screw terminal SHDSL1 SHDSL2 SHDSL3 SHDSL4 Position Signal Function 1 Line SHDSL line conductor 2 Line SHDSL line conductor XSLAN BP2XXX 2 positions screw terminal SHDSL1 SHDSL2 SHDSL1 by_pass SHDSL2 by pass Position Signal...

Страница 21: ...solated 2 B RS485 polarity B 3 A RS485 polarity A XSLAN X260 5 positions screw terminal RS422 isolated Position Signal Function 1 Tx Emission polarity 2 Tx Emission polarity 3 Com Common isolated 4 Rx Reception polarity 5 Rx Reception polarity XSLAN X220 et XSLAN X230 RJ45 connector RS232 To connect a DCE Position Signal Direction Function RJ45 1 DTR 108 OUT Data terminal ready 2 TD 103 OUT Data E...

Страница 22: ...7 OUT Data set ready 7 RTS 105 IN Request to send 8 CTS 106 OUT Clear to send OUT Signal supplied by the XSLAN IN Signal supplied by the external device 1 3 Push button Push button Pressing the PB LED Function During operation Flashing red Temporary return to the factory configuration IP address 192 168 0 128 The current configuration is not lost During power up Flashing red Return to the factory ...

Страница 23: ...lure Fast blinking red Firmware download in progress Ring Steady green The fail safe ring is established Steady red Fail safe ring failure Off Fail safe ring disabled SHDSL 1 SHDSL 2 SHDSL 3 SHDSL 4 1 to 4 Green light Slow blinking Connection in progress Steady Connection established Flashing Traffic on the link RS232 Rx Bytes received from the RS232 Tx Bytes transmitted to the RS232 RS485 Rx Byte...

Страница 24: ...product shall be connected only to equipments that comply with the IEC60950 1 or IEC62368 1 standards and that meet the following classifications IEC60950 1 Limited power circuits and SELV type 2 2 and 2 5 IEC62368 1 ES1 PS2 To avoid any risk of burns it is strongly recommended to wear gloves to handle the product in operation when the ambient temperature exceeds 30 C ...

Страница 25: ...35mm DIN rail To avoid obstructing the airflow around the unit the spacing must be at least 25 mm above and below and 10 mm left and right 5 Power supply The XSLAN has 2 power inputs allowing a redundancy power supply The supply voltage must be regulated and strictly between 10 and 60 Volt DC nominal 12 48 VDC The power consumption is 5W for XSLAN 1XXX 6W for XSLAN 2XXX and XSLAN BP2XXX and 9W for...

Страница 26: ...rfaces XSLAN X230 et XSLAN BP2230 products are electrically isolated with the same conditions except for the RS232 interfaces 7 RS232 serial connection XSLAN X220 or XSLAN X230 Cables can be provided to connect the product to DTE and DCE as follows RS232 cables Reference Connector Function CAB592 SubD 9 male To connect a DCE to the product CAB593 SubD 9 female To connect a DTE to the product CAB60...

Страница 27: ...the bus We recommend to use a shielded cable and twisted pairs When two devices or more are connected to the RS422 bus the XSLAN must be the only device to transmit data on the TX TX line towards all the other devices It means that the TX TX line of the IXSLAN must be connected to the RX RX of all the other devices of the bus Micro switches No polarization No termination resistor 470 Ohm polarizat...

Страница 28: ... extremity of the RS485 bus The polarization resistors must be enabled by one device of the bus Up to 16 devices can be connected to the bus We recommend to use a shielded cable and twisted pairs Micro switches No polarization No termination resistor 470 Ohm polarization resistors No termination resistor No polarization 120 Ohm termination resistor 470 Ohms polarization resistors 120 Ohm terminati...

Страница 29: ...ed pairs of the same cable are wound in groups of two pairs a group of two pairs rolled into each other is called a quad This type of cable is suitable However we will try to use only one pair per quad to avoid crosstalk see below Shielded cable It is better to use a shielded cable The shield must be connected to the earth at one of its ends The shield decreases the influence of the electromagneti...

Страница 30: ...he line However there may be a large potential difference between the connection points to the earth especially when the line is long Therefore to avoid a large current flowing in the shield it is recommended to connect the shield to the earth at only one end of the cable 12 4 Protecting the SHDSL switch from lightning The XSLAN is coupled to the line by a transformer which provides isolation betw...

Страница 31: ... 4200 the data rate it is recommended to wire pairs in an orderly way as shown below to make the configuration and the diagnostic easier XSLAN 4XXX XSLAN 4XXX 13 3 Daisy chain or ring connection If the SHDSL switches are connected to shape a daisy chain network or a ring network we recommend to connect the lines as shown below In that way the configuration of each SHDSL switch will be similar 13 4...

Страница 32: ......

Страница 33: ... connect the PC directly to the LAN interface of the XSLAN Subsequent changes can be made remotely Restoring the factory IP address The factory IP address 192 168 0 128 can be restored see the User guide of the product Restricted access to the administration server If you do not have access to the administration server it is probably that access has been restricted for security reasons or for othe...

Страница 34: ...e web browser Launch the web browser and then enter the IP address of the XSLAN 192 168 0 128 The Home page of the administration server is displayed Note Access to the administration server is not protected when configuring the XSLAN for the first time 1 3 Changing the configuration later Thereafter the XSLAN administration server is accessible from the Ethernet interface or remotely through the ...

Страница 35: ...utton B2 or reboot the product The product can be reached at the registered IP address Note If the IP address of the XSLAN is unknown the software tool EticFinder can be used This software detects all ETIC branded products on a local network After starting the software click on the Search button and when the product list is displayed double click on the product address to access the html server 3 ...

Страница 36: ...ministration server are lost you have to temporarily return to the factory settings access to the administration server is then free 5 Configuration steps To configure the product we advise to proceed as follows Set up the LAN interface Set up the SHDSL connections Set up the RSTP or failsafe ring redundancy protocol Set up VLAN Set up SNMP Set up QoS Set up the routing functions Set up the serial...

Страница 37: ...link depending on the wire diameter and the distance These values are indicative in noise free environment Distance versus data rate through one pair Data rate 192Kb s 1 2Mb s 2 3Mb s 5 7 Mb s 6 7 Mb s 10 Mb s 12 Mb s 15 Mb s Distance Ø 0 9 mm 13 km 8 km 6 km 3 7 km 2 5 km 1 5 km 1 km 0 7 km Distance Ø 0 4 mm 7 km 4 km 3 km 2 km 1 3 km 0 9 km 0 6 km 0 4 km ...

Страница 38: ...13 Chemin du Vieux Chêne 38240 Meylan France Tel 33 0 4 76 04 20 00 contact etictelecom com www etictelecom com ...