GETTING STARTED

 

Page 20

 

IPL-3G UMTS router

 

 
 

Installing the SIM card 

 

Before installing the SIM card into the router, its PIN code be cleared. 
The PIN code can be cleared using a usual telephone or a smart phone. 

 
Step 1  : Install the SIM card 

• 

Power off the router. 

• 

Remove the anti-steal lid at the top of the product 

• 

Press the SIM card eject button and remove the SIM card drawer. 

• 

Insert the SIM card SIM card drawer. 

• 

Slid the drawer back into the unit and make sure it locks into place. 

 
Step 2 : Check the reception signal strength 

• 

Switch-on the router 

• 

The                led first  lights red  and then green. 

• 

The power 

indicator lights green. 

• 

The  

  

reception

 

led flashes  to indicate cyclically the reception signal strength. 

The reception indicator must flash at least 2 times to ensure a reliable connection. 

If the reception led flashes only one time, it means that the reception signal is poor; 
the reception conditions have to be improved. 

If the reception led remains off or remains off, it means that the 3G service cannot be 
received at that location or that the antenna is not connected or damaged. 

• 

If the              led lights red, it signifies  that the PIN code of the SIM card 

has not been cleared. 

 

Содержание IPL-3G-E-1201

Страница 1: ...IPL 3G UMTS GPRS EDGE router ________________ INSTALLATION MANUAL Document reference 9019609 01 ________________ ...

Страница 2: ...CONNECTORS 9 6 LED INDICATORS 12 7 DIP SWITCHES 14 8 FACTORY DEFAULT PUSH BUTTON 14 9 MOUNTING THE PRODUCT ON A DIN RAIL OR REMOVING IT 15 10 COOLING 16 11 RS232 INTERFACE 16 12 RS485 INTERFACE 17 13 DIGITAL INPUT AND OUTPUT 18 GETTING STARTED 1 CONNECTING THE ANTENNA 19 2 INSTALLING THE SIM CARD 20 3 CONNECTING THE PC TO THE HTML SERVER 21 4 SETTING UP THE UMTS CONNECTION 23 5 FURTHER CONFIGURATI...

Страница 3: ... where you wish to install it Do not use the IPL 3G router in locations with a potentially explosive atmosphere like for instance petrol stations or areas where the atmosphere contains chemicals or particles The IPL 3G uses the UMTS radio network and wireless waves It is why it is is not possible to guarantee it will connect without interruption It is not possible to rely only the IPL 3G and the U...

Страница 4: ...c compatibility and Radio spectrum Matters Part 1 General requirements EN301489 7 Electromagnetic compatibility and Radio spectrum Matters Part 7 Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio EN61000 6 2 Ed 2001 Immunity EN60100 4 2 Electrostatic Discharge EN60100 4 3 Radiated Immunity EN60100 4 4 EFT Burst Immunity EN60100 4 5 Surge Immunity E...

Страница 5: ... 10 10 10 Max supply voltage VDC 60 60 60 60 30 30 60 60 Ethernet 10 100 BT 4 4 2 2 2 2 2 2 RS232 0 0 0 0 1 1 2 2 RS485 2 wires 0 0 0 0 1 1 0 0 IPL 3G E router 1400 1400B 1201 1201B 1220 1220B 1230 1230B UMTS frequency 900 2100 MHz GSM GPRS frequency 900 2100 MHz Min supply voltage VDC 10 10 10 10 10 10 10 10 Max supply voltage VDC 60 60 60 60 30 30 60 60 Ethernet 10 100 BT 4 4 2 2 2 2 2 2 RS232 0...

Страница 6: ...er software tool with which you can discover the IP address of any product manufactured by ETIC TELECOM and connected to an Ethernet network Accessories to order separately reference 90 antenna ANT210 Magnet mount antenna cable length 2 5 m ANT211 Roof mount antenna cable length 1 5 m ANT212 RS232 9 Male connector CAB592 RS232 9 Female connector CAB593 Surge protection PS02 1 ...

Страница 7: ...ection is permanent The IPL 3G provides to authorized users a remote access to the devices connected either using a fixed IP address or the DynDNS service or the M2Me_Connect service provided by ETIC TELECOM The product includes an up to date RS to IP gateway enabling to connect serial devices safely to the 3G network and the Internet IPL 3G UMTS router Page 7 ...

Страница 8: ...PRODUCT DESCRIPTION 4 Dimensions Page 8 IPL 3G UMTS router ...

Страница 9: ...PRODUCT DESCRIPTION 5 Connectors X G or E see the product identification table on page 5 IPL 3G X 1220 IPL 3G X 1230 IPL 3G X 1230 IPL 3G UMTS router Page 9 ...

Страница 10: ... 3G X 1220 or IPL 3G X 1220 B 10 to 30 VDC All other models 10 to 60 VDC 4 Power 2 GND 5 3V3 3 V DC provided by the IPL router 6 In Digital input 7 F Digital output max 50Vdc 0 6A 8 F Digital output RJ45 connector Ethernet Position Name Description 1 Tx Emission polarity 2 Tx Emission polarity 3 Rx Reception polarity 4 N C 5 N C 6 Rx Reception polarity 7 N C 8 N C RS485 screw terminal Position Nam...

Страница 11: ...03 OUT Data Emission 3 RD 104 IN Data Reception 4 DSR 107 IN Data set ready 5 SG 102 Ground 6 Not used OUT 7 CTS 106 IN Clear to send 8 RTS 105 OUT Request to send RS232 RJ45 connector port 2 To connect to a DCE to the RS232 port Position Circuit Function 1 Not used 2 TD 103 OUT Data Emission 3 RD 104 IN Data Reception 4 Not used 5 SG 102 Ground 6 Not used 7 Not used 8 Not used ...

Страница 12: ...t is ready Red The product is starting The SIM card is not present The 3G modem is in failure IPL 3G X 1220 IPL 3G X 1220 B with 1 RS232 and 1 RS485 interface Rx Flashing green Bytes received from the RS232 or RS485 to IPL Tx Flashing green Bytes transmitted to the RS22 or RS485 from IPL IPL 3G X 1230 IPL 3G X 1230 B with 2 RS232 interfaces Rx Flashing green Bytes received from the RS232 1 interfa...

Страница 13: ...cur and the data rate might be lower 81 to 90 1 flash Insufficient reception The level of the reception signal is weak errors and disconnection might occur The reception conditions must be improved to get a reliable connection 91 to 110 Always OFF No reception Control or replace the antenna or the product itself Can a communication be set with a mobile phone 111 Always ON The router is now connect...

Страница 14: ... access to the html server OFF ON The active IP is provided by the BOOTP or DHCP server ON ON Reserved SW 3 SW 4 Not used 8 Factory default push button A push button is located under the lid at the top of the product It enables to restore the factory profile To restore the factory profile switch the power on while pressing the push button until the RUN light turns green Attention Once the factory ...

Страница 15: ...ON 9 Mounting the product on a DIN rail or removing it Mounting the unit on the DIN rail This unit should be mounted on 35 mm DIN rail horizontally mounted Removing the unit from the DIN rail IPL 3G UMTS router Page 15 ...

Страница 16: ...an be tuned from 1200 to 115200 b s with parity even odd or no parity The data terminal must be less than 10 meters far from the modem Cables can be provided to connect the product to DTE and DCE as follows RS232 cables L 1m Code User connector Cable function CAB592 SubD 9 male To connect a DCE to the IPL 3G CAB593 SubD 9 female To connect a DTE to the IPL 3G CAB609 Wires To connect a device provi...

Страница 17: ... resistors 1 Kohm bus polarisation resistors are included inside the product 1K 1K SW1 B A RS485 RS485 line adaptation For a several meters long connection over the RS485 local interface it is not necessary to adapt the RS485 line For a longer distance connect a 120 Ohm resistor at each end of the line IPL 3G UMTS router Page 17 ...

Страница 18: ...ital input and output Digital output Max voltage 48 VDC Max current 500 mA Digital input Maximum voltage 20 VDC F F 7 8 Digital output 3V3 In 5 6 Digital input Page 18 IPL 3G UMTS router V IPL router I max 0 5 A V 48 VDC I 0 5 A ...

Страница 19: ... which the router has to be installed is made of metal the antenna has to be installed outside the cabinet for instance on its top The antenna must be ordered separately the models below are available 90 antenna ANT210 Magnet mount antenna ANT211 Roof antenna ANT212 ANT211 ANT212 1 50 m ...

Страница 20: ...tep 2 Check the reception signal strength Switch on the router The led first lights red and then green The power indicator lights green The reception led flashes to indicate cyclically the reception signal strength The reception indicator must flash at least 2 times to ensure a reliable connection If the reception led flashes only one time it means that the reception signal is poor the reception c...

Страница 21: ...asted string and enter it again with the keyboard Network IP address Later in the text we often speak of network address We mean the lowest value of the addresses of the network For instance if the netmask of a network is 255 255 255 0 the network address of that network is X Y Z 0 Saving and restoring the parameters file A parameters file can only be downloaded to a product having the same firmwa...

Страница 22: ...t the Internet protocol TCP IP choice and then click Properties The Internet protocol TCP IP Properties dialog box is displayed Assign to the PC an IP address in accordance with the router s IP address for instance IP address 192 168 0 100 Subnet mask 255 255 255 0 Default gateway 192 168 0 128 Close the html browser if it was open prior to the network changes Step 2 Connect the PC to the router w...

Страница 23: ...IPL 3G is now connected to the UMTS network Remark If the IPL 3G must connect to a private netxork report to the user manual for detailed informatios about that page 5 Further configuration The IPL 3G provides numerous useful functions to build a reliable and secure wireless industrial network We list hereafter some of them and the attached menu of the html server Function Menu Protecting the acce...

Страница 24: ...e IPL 3G has been designed and is manufactured by ETIC TELECOM 13 Chemin du vieux chêne 38240 MEYLAN FRANCE TEL 33 4 76 04 20 05 FAX 33 4 76 04 20 01 E mail hotline etictelecom com Web www etictelecom com ...

Отзывы: