INSTALLATION
XSLAN SHDSL switch
User’s guide ref 9014709-02
Page 15
1.3
DIP switches and push-button
DIP switches
SW 1 SW 2
Management
OFF
OFF
The current IP@ of the product is the stored IP @
ON
OFF
The active IP@ of the product is the factory IP@ : 192.168.0.128
No login and password are required to access to the html server
OFF
ON
The active IP@ is provided by the BOOTP or DHCP server
ON
ON
No IP @ is assigned to the product; DIP switch configuration
SW 3 SW 4
SW 5
Shdsl port 1
OFF
OFF
OFF
NTU mode
OFF
OFF
ON
LTU mode - Auto
OFF
ON
OFF
LTU mode – 2304 kbit/s
OFF
ON
ON
LTU Mode – 2048 kbit/s
ON
OFF
OFF
LTU Mode – 1536 kbit/s
ON
OFF
ON
LTU Mode – 1024 kbit/s
ON
ON
OFF
LTU Mode – 512 kbit/s
ON
ON
ON
LTU Mode – 256 kbit/s
SW 6 to SW 12
Not used - Must be left OFF
Push-button :
A push-button is located close to the DIP switches.
It enables to restore the factory profile.
To restore the factory profile, switch the power on while pressing the
push-button until the OPERATION led turns green.
Attention
: Once the factory profile has been restored, the stored
configuration is lost.