INSTALLATION
DOC_DEV_RFM_User Guide_A
Page 17
2
Safety instructions
RFM must be installed by a qualified operator, in a cabinet or computer rack providing an enclosure against
fire.
RFM must only be connected to equipment that complies with IEC60950-1 or IEC62368-1 standards that meet
the following classifications:
•
IEC60950-1 : limited power source and interconnection circuit of following type: TBTS
–
§2.2 et 2.5
•
IEC62368-1 : ES1 & PS2
To avoid any risk of burns, it is strongly recommended to wear gloves when handling the product in
operation when the ambient temperature exceeds 30 ° C.
3
Ventilation
The product is designed to be installed in a computer cabinet or rack.
To avoid any heating, in particular when the ambient temperature can rise in the cabinet, take care to leave a
space of 1 cm on each side and 2.5 cm above and below the product to facilitate the heat flow.
4
Grounding
For reasons of safety and electromagnetic compatibility, the box must be connected to the protective earth of
the installation by means of its power cable.