background image

 

 

Copyright 

©

2014 EtherWAN Systems, Inc.

  

  Page 1 

 

All Rights Reserved 

EX70900 rev. 1.0 
12/2/2014 

 

 

Unpacking 

Unpack the items. Your package should include: 

 

One EX70900 Series hardened managed 

switch 

 

Rack-mounting hardware brackets 

 

One CD containing this user’s guide 

If items are missing or damaged, notify your 

EtherWAN representative. Keep the carton and 

packing material. 

What Else You Need 

 

Appropriate cables for data ports 

 

Personal computer or laptop 

Select a Location 

 

Desktop installations: Mount on a flat table 

or shelf surface. 

 

Rack installations: Use a 19-inch (48.3-

centimeter) EIA standard equipment rack 

that is grounded and physically secure.  

 

Identify a power source within 6 feet (1.8 

meters). 

 

Choose a dry area with ambient temperature 

between -40 and 75ºC (-40 and 167ºF). 

 

Keep away from heat sources, sunlight, warm 

air exhausts, hot-air vents, and heaters. 

 

Be sure there is adequate airflow. 

 

Keep the switch at least 6 ft. (1.83 m) away 

from the nearest source of electromagnetic 

noise, such as a photocopy machine. 

 

Connect to the Data Ports 

Depending on the model, your switch can have 

the following ports: 

 

4, 6, or 8 10/100/1000Base-TX ports 

 

0, 1, or 2 Gigabit ports 

10/100/1000Base-TX Ports 

These ports can connect to devices such as an IP 

surveillance camera or a Voice Over Internet 

Protocol (VoIP) phone. 

A.

 

Insert one end of an appropriate cable into a 

switch port.  

B.

 

Connect the other end into the Ethernet port 

of the device.  

C.

 

Repeat steps A and B for each additional 

device you want to connect to the switch. 

Gigabit Ports 

Some switch models have 1 or 2 1000Base-

SX/LX/BX ports. You can connect these ports to 

network devices such as a computer, printer, 

network video recorder (NVR), network storage, 

or they can connect to the network itself. 
Combo ports operate in “either/or” fashion. This 

means that attaching to a 1 Gbps combo port 

renders the equivalent partner combo port 

unavailable. See the following example.  
 

 

 

 

 

Apply Power 

The switch has two pairs of power inputs:  

 

A 12-48VDC terminal block 

 

A 12VDC jack 

Only one power input is required to operate the 

switch. However, redundant power supply 

functionality is supported. 

Terminal Block 

The switch provides two power inputs on a 12-

48VDC terminal block. Only one power input is 

required to operate the switch. The terminal 

block has 5 terminal posts.  

 

 

EX70900 Managed Switch Installation Guide 