background image

EX42008 series                                                                            Hardened Ethernet Switch                                                            www.etherwan.com 

 

This quick start guide describes how to install and use the Hardened Ethernet Switch. 

Capable of operating at temperature extremes of -40°C to +75°C, this is the Switch of 
choice for harsh environments constrained by space. 

The Terminal Block and Power Inputs 

 

 

Physical Description 

The Port Status LEDs 

 

 

 

LED State 

Indication 

Steady Power 

on. 

 

Power 1, 2 (Green)

Off Power 

off. 

Steady 

Relay starts alarm. 

 

Fault (Red) 

Off Relay 

non-alarm. 

10/100TX or 100FX/BX Ports 

Steady 

A valid network connection established. 

Blinking 

Transmitting or receiving data. 

Act stands for Activity. 

 

Link/Act (Green) 

Off No 

link. 

Power Input Assignment 

12~48VDC 

Power 1 

Power Ground 

12~48VDC 

Power 2 

Power Ground 

 

Earth Ground 

Terminal Block 

Relay Output Rating 

1A @ 250VAC 

 
DC Terminal Block Power Input: The DC Terminal Block power input can be used to 
power up this Switch. 

 

DIP Switch Settings 

 

 

DIP No.

On 

Off 

Port 1 Alarm Enable.

Port 1 Alarm Disable.

Port 2 Alarm Enable.

Port 2 Alarm Disable.

Port 3 Alarm Enable.

Port 3 Alarm Disable.

Port 4 Alarm Enable.

Port 4 Alarm Disable.

Port 5 Alarm Enable.

Port 5 Alarm Disable.

Port 6 Alarm Enable.

Port 6 Alarm Disable.

Port 7 Alarm Enable.

Port 7 Alarm Disable.

Port 8 Alarm Enable.

Port 8 Alarm Disable.

 

1                                                                                                                                     

W70G-EX42008Q1 

Отзывы: