This quick start guide describes how to install and use the Industrial Ethernet Switch / 
Media Converter. 

Capable of operating at temperature extremes of -10°C to +60°C, 

this is the Switch / Media Converter of choice for harsh environments constrained by 
space. 

The Terminal Block and Power Input 

 

Physical Description 

The Port Status LEDs 

 

LED State 

Indication 

10/100TX or 100FX/BX 

Steady 

A valid network connection established. 

LINK stands for LINK. 

LINK/ACT 

Flashing 

Transmitting or receiving data. 

ACT stands for ACTIVITY. 

Steady 

The port is transferring at 100Mbps. 

100 

Off 

The port is transferring at 10Mbps If this LED is dark. 

 

The Terminal Block 

PWR Power 

Input 

GND Power 

Ground 

 

Earth Ground 

 

DC Terminal Block Power Input: The DC Terminal Block power input can be used to 
power up this Switch / Media Converter. 

 

CAUTION

: This equipment is designed to permit the connection of the earthed 

conductor of the DC supply circuit to the earthing conductor at the equipment. 
 
If this connection is made, all of the following conditions must be met: 

  This equipment shall be connected to directly to the DC supply system earthing 

electrode conductor or to a bonding jumper from an earthing terminal bar or bus to 
which the DC supply system earthing electrode conductor is connected. 

  This equipment shall be located in the same immediate area (such as, adjacent 

cabinets) as any other equipment that has a connection between the earthed 
conductor of the same DC supply circuit and the earthing conductor, and also the 
point of earthing of the DC system. The DC system shall not be earthed 
elsewhere. 

  The DC supply source is to be located within the same premises as the 

equipment. 

  Switching or disconnecting devices shall not be in the earthed circuit conductor 

between the DC source and the point of connection of the earthing electrode 
conductor. 

 

 